HIPS 4440 TOTAL EU
139
Form:Granules | Grade:Injection grade
Properties:
High impact resistanceDimensional stabilityAcceptable food contactGood dimensional stabilitHigh impact resistance
Typical Applications:
sheathBusiness equipmentEnterprise Equipmentsheath
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | sheath | Business equipment | Enterprise Equipment | sheath |
| Properties: | High impact resistance | Dimensional stability | Acceptable food contact | Good dimensional stabilit | High impact resistance |
Certificates
No Data...
Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| density | ISO 1183 | 1.04 | ||
| Water absorption rate | 24hr,23℃ | ISO 62 | 0.10 | % |
| melt mass-flow rate | 200℃,5kg | ISO 1133 | 10 | g/10min |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | ISO 2039-2 | 76 | R scale | |
| Impact strength of cantilever beam gap | ISO 180/1A | 10.00 | KJ/m | |
| Charpy Notched Impact Strength | 23℃ | ISO 179/1eU | 9.00 | KJ/m |
| Bending modulus | ISO 178 | 2000 | Mpa | |
| Tensile creep modulus | 1hr | ISO 899-1 | 2000 | Mpa |
| Fracture strain | ISO 527-2 | 55 | % | |
| Fracture stress | ISO 527-2 | 20.0 | Mpa | |
| Tensile modulus | ISO 527-2 | 2050 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | Transverse | ISO 11359-2 | 0.000090 | cm/cm/℃ |
| Vicat softening temperature | 50℃/h,B(50N) | ISO 306 | 88.0 | °C |
| ISO 306/B50 | 88.0 | °C | ||
| ISO 306/A50 | 96.0 | °C | ||
| Hot deformation temperature | 1.80MPa | ISO 75-2 | 89.5 | °C |
| 1.80MPa,Annealed | ISO 75-2/A | 90.0 | °C | |
| 1.80MPa,Unannealed | ISO 75-2/A | 74.0 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | ISO 294-4 | 0.40-0.70 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric strength | IEC 60243-1 | 150.00 | KV/mm | |
| Surface resistivity | IEC 60093 | 1E+13 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.