PA66 Vydyne® R530 NAT

0
  • Properties:
    Filler
    glass fiber reinforced material
    30%
    filler by weight
  • Usages:
    Parts under the hood of a car

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityISO 11831.37 g/cm³
Shrinkage rateISO 294-40.90 %
Shrinkage rateISO 294-40.40 %
Water absorption rateISO 620.90 %
Water absorption rateISO 621.9 %
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL 94HB
UL flame retardant ratingUL 94HB
UL flame retardant ratingUL 94HB
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapISO 18010 kJ/m²
Impact strength of cantilever beam gapISO 18012 kJ/m²
Charpy Notched Impact StrengthISO 17910 kJ/m²
Charpy Notched Impact StrengthISO 17911 kJ/m²
Impact strength of simply supported beam without notchISO 17965 kJ/m²
Impact strength of simply supported beam without notchISO 17975 kJ/m²
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile strainISO 527-23.0 %
Flexural modulusISO 1789600 MPa
bending strengthISO 178270 MPa
Poisson's RatioISO 5270.40
Tensile modulusISO 527-210000 MPa
tensile strength ISO 527-2195 MPa
Electrical performanceTest ConditionTest MethodTest Result
High Voltage Arc Traceability Rate (HVTR)UL 746PLC 1
Hot wire ignition (HWI)UL 746PLC 4
Volume resistivityIEC 600931E+14 ohms·cm
dielectric strengthIEC 6024324 kV/mm
arc resistanceASTM D495PLC 5
Compared to the Leakage Tracking Index (CTI)IEC 60112PLC 0
High arc combustion index (HAI)UL 746PLC 0
High arc combustion index (HAI)UL 746PLC 0
High arc combustion index (HAI)UL 746PLC 0
Hot wire ignition (HWI)UL 746PLC 4
Hot wire ignition (HWI)UL 746PLC 4
Thermal performanceTest ConditionTest MethodTest Result
RTI StrUL 746115 °C
RTI StrUL 746120 °C
RTI StrUL 746120 °C
Heat distortion temperatureISO 75-2/B260 °C
Linear coefficient of thermal expansionISO 11359-22.2E-05 cm/cm/°C
Linear coefficient of thermal expansionISO 11359-21.1E-04 cm/cm/°C
RTI ElecUL 746120 °C
RTI ElecUL 746120 °C
RTI ElecUL 746120 °C
RTI ImpUL 74685.0 °C
RTI ImpUL 74685.0 °C
RTI ImpUL 746105 °C
Heat distortion temperatureISO 75-2/A250 °C
melting temperatureISO 11357-3260 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.