PPS 4332L6 CELANESE USA
35
Form:Granules | Grade:Injection grade
Properties:
Flame retardant
Typical Applications:
Automotive sectorElectronic fieldElectrical field
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive sector | Electronic field | Electrical field |
| Properties: | Flame retardant |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 30 | kJ/m² |
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 10 | kJ/m² |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2/1A/1 | 21500 | Mpa | |
| tensile strength | Break | ISO 527-2/1A/5 | 160 | Mpa |
| Break | ISO 527-2/1A/5 | 160 | MPa | |
| bending strength | 23°C | ISO 178 | 260 | Mpa |
| Bending modulus | 23°C | ISO 178 | 21000 | Mpa |
| Tensile modulus | ISO 527-2/1A/1 | 21500 | MPa | |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eA | 10 | kJ/m² |
| bending strength | 23°C | ISO 178 | 260 | MPa |
| Bending modulus | 23°C | ISO 178 | 21000 | MPa |
| Tensile strain | Break | ISO 527-2/1A/5 | 1.2 | % |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 30 | kJ/m² |
| Tensile strain | Break | ISO 527-2/1A/5 | 1.2 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | flow | ISO 11359-2 | 0.000012 | cm/cm/°C |
| Hot deformation temperature | 8.0MPa,Unannealed | ISO 75-2/C | 220 | °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 270 | °C | |
| Linear coefficient of thermal expansion | TD | ISO 11359-2 | 3.1E-05 | cm/cm/°C |
| MD | ISO 11359-2 | 1.4E-05 | cm/cm/°C | |
| Transverse | ISO 11359-2 | 0.000053 | cm/cm/°C | |
| Hot deformation temperature | 8.0MPa,Unannealed | ISO 75-2/C | 229 | °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 250 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Saturation,23°C | ISO 62 | 0.020 | % |
| Shrinkage rate | TD | ISO 294-4 | 0.30-0.70 | % |
| density | ISO 1183 | 1.95 | g/cm³ | |
| ASTM D792 | 1.95 | g/cm³ | ||
| Shrinkage rate | MD | ISO 294-4 | 0.20-0.60 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.