Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
viscosity number | | ISO307 | 145 cm³/g |
hardness | Test Condition | Test Method | Test Result |
---|
| | ISO2039-1 | 230 Mpa |
flammability | Test Condition | Test Method | Test Result |
---|
burning rate | | ISO3795 | <30 mm/min |
UL flame retardant rating | | IEC60695-11-10,-20 | HB |
UL flame retardant rating | | IEC60695-11-10,-20 | HB |
Burning wire flammability index | | IEC60695-2-12 | -- °C |
Burning wire flammability index | | IEC60695-2-12 | -- °C |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO527-2/1A/1 | 11000 Mpa |
Tensile stress | | ISO527-2/1A/5 | 180 Mpa |
Tensile strain | | ISO527-2/1A/5 | 3.4 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of simply supported beam without notch | | ISO179/1eU | 70 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179/1eU | 90 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC60093 | >1.0E+15 ohms |
Volume resistivity | | IEC60093 | >1.0E+13 ohms·cm |
CTI | | IEC60112 | 450 V |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ISO75-2/Bf | 220 °C |
| | ISO75-2/Af | 210 °C |
vicat | | ISO306/B50 | 210 °C |
BallPressure Test | | IEC60695-10-2 | Pass |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.