PA6 9B24200 YUV 4Plas
Properties:
Additive UV stabilizer properties laser marking good UV resistance moderate impact resistance
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Additive | UV stabilizer properties | laser marking | good UV resistance | moderate impact resistance |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 9.0 | kJ/m² |
| 23°C | ISO 180/1A | 11 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.6mm | UL 94 | HB | |
| Hot filament ignition temperature | 2.0mm | IEC 60695-2-13 | 650 | °C |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 11.0 | kJ/m² |
| Tensile modulus | 23°C | ISO 527-2/5 | 2600 | MPa |
| tensile strength | Break,23°C | ISO 527-2/5 | 75.0 | MPa |
| Tensile strain | Break,23°C | ISO 527-2/5 | 35 | % |
| tensile strength | Break, 23°C | ISO 527-2/5 | 75.0 | MPa |
| Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 9.0 | kJ/m² |
| Tensile modulus | 23°C | ISO 527-2/5 | 2600 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8 MPa, Unannealed | ISO 75-2/A | 160.0 | °C |
| Vicat softening temperature | ISO 306/B | 170.0 | °C | |
| Melting temperature | ISO 11357 | 223 | °C | |
| Vicat softening temperature | ISO 306/B | 170 | °C | |
| Melting temperature | ISO 11357 | 223 | °C | |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 160 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 2.5 | % |
| density | ISO 1183 | 1.12 | g/cm³ | |
| Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 2.5 | % |
| density | ISO 1183 | 1.12 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 | ||
| other | UL 阻燃等级,1.60 mm | UL 94 | HB | |
| Hot filament ignition temperature | 2.00 mm | IEC 60695-2-13 | 650 | °C |
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.