plas
Log In

IIR Melos™ FM 989 MELOS GERMANY

0
  • Usages:
    Wire and cable applications
  • Compare

Technical Data Sheet

mechanical propertiesTest ConditionTest MethodTest Result
Tensile strainBreakIEC 811-1-1>20 %
tensile strengthIEC 811-1-1>0.500 MPa
Physical propertiesTest ConditionTest MethodTest Result
Mooney viscosityML1+4,100°CDIN 5352355 MU
densityISO 1183/A1.91 g/cm³
Electrical performanceTest ConditionTest MethodTest Result
Volume resistivity27°CVDE0472>1.0E+12 ohms·cm
Surface resistivityVDE0472>1.0E+9 ohms
hardnessTest ConditionTest MethodTest Result
Shore hardnessShoreAISO 761975
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.