Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Water absorption rate | ISO 62 | 0.020 % | |
ISO 62 | 0.010 % | ||
density | ISO 1183 | 1.27 g/cm³ | |
Shrinkage rate | ISO 294-4 | 0.30 to 0.50 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
tensile strength | Break | ISO 527-2 | 80.0 MPa |
Tensile strain | Break | ISO 527-2 | 2.0 to 4.0 % |
Flexural modulus | ISO 178 | 6000 MPa | |
bending strength | ISO 178 | 115 MPa | |
Impact strength of cantilever beam gap | ISO 180/1A | 15 kJ/m² | |
Suspended wall beam without notch impact strength | ISO 180/1U | 45 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Surface Resistivity | ASTM D257 | 10 到 1.0E+3 ohm |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ISO 75-2/A | 140 ℃ | |
Linear coefficient of thermal expansion | ISO 11359-2 | 0.000045 cm/cm/℃ | |
RTI Imp | UL 746 | 75.0 ℃ | |
UL flame retardant rating | UL 94 | HB |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.