PA6 Latamid 6 H2 G/30-V0CT1

0
  • Properties:
    Filler
    glass fiber reinforced material
    30%
    filler by weight

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
Shrinkage rateISO294-40.50to0.70 %
Shrinkage rateISO294-40.25to0.45 %
Water absorption rateISO620.30 %
densityISO11831.54 g/cm³
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL94V-0
UL flame retardant ratingUL94V-0
UL flame retardant ratingUL94V-0
Burning wire flammability indexIEC60695-2-12960 °C
Burning wire flammability indexIEC60695-2-12960 °C
Hot filament ignition temperatureIEC60695-2-13800 °C
Hot filament ignition temperatureIEC60695-2-13800 °C
Limiting Oxygen IndexASTMD286328 %
Supplementary InformationTest ConditionTest MethodTest Result
Dimensional Stability60.0
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile stressISO527-2/5125 MPa
Tensile stressISO527-2/580.0 MPa
Tensile stressISO527-2/560.0 MPa
Tensile stressISO527-2/550.0 MPa
Tensile stressISO527-2/540.0 MPa
Tensile strainISO527-2/52.0 %
Tensile strainISO527-2/54.5 %
Tensile strainISO527-2/56.0 %
Tensile modulusISO527-2/111000 MPa
Tensile modulusISO527-2/17400 MPa
Tensile modulusISO527-2/15100 MPa
Tensile modulusISO527-2/14200 MPa
Tensile modulusISO527-2/13600 MPa
Tensile strainISO527-2/57.0 %
Tensile strainISO527-2/57.5 %
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO179/1eA7.0 kJ/m²
Charpy Notched Impact StrengthISO179/1eA8.0 kJ/m²
Impact strength of simply supported beam without notchISO179/1eU35 kJ/m²
Impact strength of simply supported beam without notchISO179/1eU40 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
CTIIEC60112400 V
Thermal performanceTest ConditionTest MethodTest Result
ISO75-2/B215 °C
ISO75-2/A185 °C
Continuous use temperature115 °C
vicatISO306/B50195 °C
ISO11359-21.5E-05 cm/cm/°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Contact Us

Get App

Top