Biodeg Polymers Biocycle 189C-1 BAAF
0
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of cantilever beam gap | -- | ISO 180/1A | 21 kJ/m² |
| -- | ASTM D256 | 23 J/m |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Bending modulus | -- | ISO 178 | 2650 MPa |
| -- | ASTM D790 | 2600 MPa | |
| elongation | Break | ASTMD638 | 2.2 % |
| tensile strength | -- | ASTM D638 | 30.0 MPa |
| Yield | ISO 527-2 | 30.0 MPa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 0.45MPa,Unannealed | ASTM D648 | 121 °C |
| Melting temperature | ASTM D3418 | 165to170 °C | |
| Vicat softening temperature | ASTMD1525 | 135 °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTMD648 | 70.0 °C |
| 0.45MPa,Unannealed | ISO 75-2/B | 120 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| melt mass-flow rate | 190°C/2.16kg | ASTMD1238 | 15 g/10min |
| density | ASTMD792 | 1.30 g/cm³ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.