PA66 A30SFN31 LANXESS GERMANY
60
Form:Granules | Grade:Flame retardant grade
Properties:
Flame retardantHigh mobility
Typical Applications:
Electronic fieldElectrical fieldAutomotive sector
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Electronic field | Electrical field | Automotive sector |
| Properties: | Flame retardant | High mobility |
Certificates

Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | -30℃-30°C | ISO 179/1eU | 50 | kJ/m² |
| 23℃23°C | ISO 179/1eU | 60 | kJ/m² | |
| Impact strength of cantilever beam gap | 23℃23℃ | ISO 180-1A | < 10 | kJ/m² |
| Suspended wall beam without notch impact strength | -30℃-30°C | ISO 180/1U | 55 | kJ/m² |
| 23℃23°C | ISO 180/1U | 55 | kJ/m² | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | 23℃23℃ | ISO 527-1-2 | 3800 | Mpa |
| tensile strength | Yield,23℃Yield,23℃ | ISO 527-2/50 | 85 | Mpa |
| Tensile strain | Yield,23℃Yield,23℃ | ISO 527-2/50 | 4.1 | % |
| Bending modulus | 23℃23℃4 | ISO 178-A | 3700 | Mpa |
| bending strength | 3.50% Strain3.5% Strain | ISO 178-A | 120 | Mpa |
| 23℃23°C | ISO 178 | 125 | Mpa | |
| Bending strain | 23°C | 5.8 | % | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | B120B120 | ISO 306/B120 | 230 | °C |
| Melting temperature | ISO 11357-3 | 265 | °C | |
| Linear coefficient of thermal expansion | TD:23~55℃TD:23 to 55℃ | ISO 11359-2 | 0.000070 | 1/℃ |
| MD:23~55℃MD:23 to 55℃ | ISO 11359-2 | 0.000080 | 1/℃ | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | 23°C | ISO 1183 | 1.17 | g/cm³ |
| Shrinkage rate | TD:270℃,2.0 mmAcross Flow : 518°F, 0.0787 in 22 | ISO 294-4 | 1.1 | % |
| TD:120℃,2.0 mm,2 hrsAcross Flow : 120°C, 2 hr, 2.00 mm 33 | ISO 294-4 | 0.1 | % | |
| MD:270℃,2.0 mmFlow : 518°F, 0.0787 in 22 | ISO 294-4 | 1.1 | % | |
| MD:120℃,2.0 mm,2 hrsFlow : 120°C, 2 hr, 2.00 mm 33 | ISO 294-4 | 0.1 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | 1000000000000000 | ohms | |
| Volume resistivity | 23℃23℃ | IEC 60093 | 100000000000000 | ohms·cm |
| Dielectric strength | 23 ℃,1 mm23℃,1.00 mm | IEC 60243-1 | 30 | KV/mm |
| Relative permittivity | 23℃,100 Hz23°C, 100 Hz | IEC 60250 | 4 | |
| 23℃,1 MHz23°C, 1 MHz | IEC 60250 | 4 | ||
| Dissipation factor | 23℃,100 Hz23°C, 100 Hz | IEC 60250 | 0.012 | |
| 23℃,1 MHz23°C, 1 MHz | IEC 60250 | 0.019 | ||
| Compared to the anti leakage trace index | Solution ASolution A | IEC 60112 | PLC 0 | |
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| 0.40 mm??0.40 mm | 0.40mm | UL 94 | V-0 | |
| Glow wire combustion index (GWFI) | 0.40 mm0.40 mm | IEC 60695-2-12 | 960 | °C |
| Ignition temperature of heating wire | 0.4 mm0.40 mm | IEC 60695-2-13 | 775 | °C |
| Ultimate Oxygen Index | ISO 4589-2 | 34 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.