Share
Add to Compare

PA66 A30SFN31 LANXESS GERMANY

60

Form:Granules | Grade:Flame retardant grade

Properties:
Flame retardantHigh mobility
Typical Applications:
Electronic fieldElectrical fieldAutomotive sector
Product Description
Certificates(1)
Datasheet

Product Description

Typical Applications:Electronic field | Electrical field | Automotive sector
Properties:Flame retardant | High mobility

Certificates

UL
UL

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch-30℃-30°CISO 179/1eU50kJ/m²
Impact strength of simply supported beam without notch23℃23°CISO 179/1eU60kJ/m²
Impact strength of cantilever beam gap23℃23℃ISO 180-1A< 10kJ/m²
Suspended wall beam without notch impact strength-30℃-30°CISO 180/1U55kJ/m²
Suspended wall beam without notch impact strength23℃23°CISO 180/1U55kJ/m²
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulus23℃23℃ISO 527-1-23800Mpa
tensile strengthYield,23℃Yield,23℃ISO 527-2/5085Mpa
Tensile strainYield,23℃Yield,23℃ISO 527-2/504.1%
Bending modulus23℃23℃4ISO 178-A3700Mpa
bending strength3.50% Strain3.5% StrainISO 178-A120Mpa
bending strength23℃23°CISO 178125Mpa
Bending strain23°C5.8%
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Vicat softening temperatureB120B120ISO 306/B120230°C
Melting temperatureISO 11357-3265°C
Linear coefficient of thermal expansionTD:23~55℃TD:23 to 55℃ISO 11359-20.0000701/℃
Linear coefficient of thermal expansionMD:23~55℃MD:23 to 55℃ISO 11359-20.0000801/℃
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
density23°CISO 11831.17g/cm³
Shrinkage rateTD:270℃,2.0 mmAcross Flow : 518°F, 0.0787 in 22ISO 294-41.1%
Shrinkage rateTD:120℃,2.0 mm,2 hrsAcross Flow : 120°C, 2 hr, 2.00 mm 33ISO 294-40.1%
Shrinkage rateMD:270℃,2.0 mmFlow : 518°F, 0.0787 in 22ISO 294-41.1%
Shrinkage rateMD:120℃,2.0 mm,2 hrsFlow : 120°C, 2 hr, 2.00 mm 33ISO 294-40.1%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Surface resistivityIEC 600931000000000000000ohms
Volume resistivity23℃23℃IEC 60093100000000000000ohms·cm
Dielectric strength23 ℃,1 mm23℃,1.00 mmIEC 60243-130KV/mm
Relative permittivity23℃,100 Hz23°C, 100 HzIEC 602504
Relative permittivity23℃,1 MHz23°C, 1 MHzIEC 602504
Dissipation factor23℃,100 Hz23°C, 100 HzIEC 602500.012
Dissipation factor23℃,1 MHz23°C, 1 MHzIEC 602500.019
Compared to the anti leakage trace indexSolution ASolution AIEC 60112PLC 0
flame retardant performanceTest ConditionTest MethodTest ResultTest Unit
0.40 mm??0.40 mm0.40mmUL 94V-0
Glow wire combustion index (GWFI)0.40 mm0.40 mmIEC 60695-2-12960°C
Ignition temperature of heating wire0.4 mm0.40 mmIEC 60695-2-13775°C
Ultimate Oxygen IndexISO 4589-234%
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.