PC 4702-10 STYRON US
11
Form:Granules | Grade:Injection grade
Properties:
heat-resistingFlame retardant Excellent demolding perfrigidityGood dimensional stabilit
Typical Applications:
Fitness equipmentElectronic fieldElectrical fieldSuitable for producing electric toolsElectrical and information technology products.
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Fitness equipment | Electronic field | Electrical field | Suitable for producing electric tools | Electrical and information technology products. |
| Properties: | heat-resisting | Flame retardant | Excellent demolding perf | rigidity | Good dimensional stabilit |
Certificates
No Data...
Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| density | ASTM D-792 | 1370 | kg/m² | |
| melt mass-flow rate | 300℃,1.2kg | ASTM D-1238 | 15 | g/10min |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | 23℃ | ASTM D-256 | 75 | J/m |
| elongation | Break | ASTM D-638 | 4 | % |
| tensile strength | Break | ASTM D-638 | 80 | Mpa |
| Suspended wall beam without notch impact strength | 23℃ | ASTM D-256 | 380 | J/m |
| Tensile modulus | ASTM D-638 | 6000 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.82MPa,Annealed | ASTM D-648 | 146 | °C |
| 1.82MPa,Unannealed | ASTM D-648 | 135 | °C | |
| Ball indentation temperature | IEC 598-1 | >125 | °C | |
| Vicat softening temperature | 50N,50℃/hr | ASTM D-1525 | >125 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 3.2mm | V-0 | ||
| Glow wire combustion index (GWFI) | IEC 695-2-1 | 960 | °C | |
| UL flame retardant rating | 1.6mm | V-0 | ||
| Shrinkage rate | ASTM D-955 | 0.002-0.004 | mm/mm | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the Leakage Traceability Index (CTI) | 2.0mm | IEC 112 | 175 | V |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.