
PSU P-1700 PK1172 SOLVAY JAPAN
39
Form:Granules
Properties:
dimensional stability Electron beam disinfectioRadiopableRadiation disinfectionPressure cooker disinfectGood disinfection performEthylene oxide disinfectiAnti gamma radiationChemical resistanceAlkali resistantAlcohol resistanceheat-resistingAcid resistanceResistance to hydrocarbonDetergent resistantSteam resistantThermal disinfectionHigh toughnessBiocompatibilityFood contact complianceHydrolysis resistanceDisinfect with steamExcellent appearance
Typical Applications:
Electrical fieldElectronic fieldElectrical componentsElectrical appliancesvalveValve componentsIndustrial componentsPipeline componentsPipeline componentsHome appliance componentsAutomotive sectorFood service sectorSurgical instrumentsMicrowave cookerDental application fieldMedical suppliesNursing suppliesMedical devicesMedical devices
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electrical field | Electronic field | Electrical components | Electrical appliances | valve | Valve components | Industrial components | Pipeline components | Pipeline components | Home appliance components | Automotive sector | Food service sector | Surgical instruments | Microwave cooker | Dental application field | Medical supplies | Nursing supplies | Medical devices | Medical devices |
| Properties: | dimensional stability | Electron beam disinfectio | Radiopable | Radiation disinfection | Pressure cooker disinfect | Good disinfection perform | Ethylene oxide disinfecti | Anti gamma radiation | Chemical resistance | Alkali resistant | Alcohol resistance | heat-resisting | Acid resistance | Resistance to hydrocarbon | Detergent resistant | Steam resistant | Thermal disinfection | High toughness | Biocompatibility | Food contact compliance | Hydrolysis resistance | Disinfect with steam | Excellent appearance |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | ASTM D1822 | 420 | kJ/m² | |
| ASTM D256 | 69 | J/m | ||
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Hot filament ignition temperature | 1.6to6.0mm | IEC 60695-2-13 | 850 | °C |
| 0.8mm | IEC 60695-2-13 | 875 | °C | |
| Burning wire flammability index | 1.6to6.0mm | IEC 60695-2-12 | 960 | °C |
| 0.8mm | IEC 60695-2-12 | 850 | °C | |
| UL flame retardant rating | 4.5mm | UL 94 | V-0 | |
| 1.5mm | UL 94 | HB | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ASTM D790 | 106 | Mpa | |
| Bending modulus | ASTM D790 | 2690 | Mpa | |
| elongation | Break | ASTM D638 | 50to100 | % |
| tensile strength | ASTM D638 | 70.3 | Mpa | |
| Tensile modulus | ASTM D638 | 2480 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | MD | ASTM D696 | 5.6E-05 | cm/cm/°C |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 174 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 24hr | ASTM D570 | 0.30 | % |
| Shrinkage rate | MD | ASTM D955 | 0.70 | % |
| melt mass-flow rate | 343°C/2.16kg | ASTM D1238 | 6.5 | g/10min |
| density | ASTM D792 | 1.24 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric constant | 1MHz | ASTM D150 | 3.02 | |
| Dissipation factor | 60Hz | ASTM D150 | 7E-04 | |
| 1kHz | ASTM D150 | 1E-03 | ||
| Dielectric constant | 1kHz | ASTM D150 | 3.04 | |
| 60Hz | ASTM D150 | 3.03 | ||
| Dielectric strength | ASTM D149 | 17 | KV/mm | |
| Volume resistivity | ASTM D257 | 3E+16 | ohms·cm | |
| Dissipation factor | 1MHz | ASTM D150 | 6E-03 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.