Share
Add to compare

PET SCHULADUR® E GF 50 A SCHULMAN USA

Properties:
Filler glass fiber reinforced material 50% filler by weight
Product Description
Certificates(0)
Datasheet

Product Description

Properties:Filler | glass fiber reinforced material | 50% | filler by weight

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Charpy Notched Impact Strength-30°CISO 179/1eA10kJ/m²
Charpy Notched Impact Strength23°CISO 179/1eA10kJ/m²
Impact strength of simply supported beam without notch-30°CISO 179/1eU45kJ/m²
Impact strength of simply supported beam without notch23°CISO 179/1eU50kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
Burning rateISO 379520mm/min
UL flame retardant rating1.5mmIEC 60695-11-10,-20HB
UL flame retardant rating3.0mmIEC 60695-11-10,-20HB
Burning wire flammability index1.5mmIEC 60695-2-12700°C
Burning wire flammability index3.0mmIEC 60695-2-12800°C
Hot filament ignition temperature1.5mmIEC 60695-2-13725°C
Hot filament ignition temperature3.0mmIEC 60695-2-13825°C
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulusISO 527-2/1A/120000MPa
tensile strengthBreakISO 527-2/1A/5195MPa
Tensile strainBreakISO 527-2/1A/51.5%
Bending modulusISO 17817000MPa
bending strengthISO 178290MPa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature0.45MPa,UnannealedISO 75-2/Bf250°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/Af233°C
Vicat softening temperature--ISO 306/A50247°C
Vicat softening temperature--ISO 306/B50235°C
Ball Pressure Test200°CIEC 60695-10-2Pass
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityISO 1183/A1.79g/cm³
Melt Volume Flow Rate (MVR)280°C/5.0kgISO 113315.0cm³/10min
Water absorption rateEquilibrium,23°C,50%RHISO 620.20%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Surface resistivityIEC 60093>1.0E+15ohms
Volume resistivityIEC 60093>1.0E+13ohms·cm
Compared to the anti leakage trace indexIEC 60112PLC 4
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.