ABS INSTRUC PCABSGF20MD USA Infinity LTL
Properties:
Filler glass fiber reinforced material 20% filler by weight
Typical Applications:
Medical and nursing supplies
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Medical and nursing supplies |
| Properties: | Filler | glass fiber reinforced material | 20% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | ASTM D256 | 110 | J/m | |
| ASTM D4812 | 530to640 | J/m | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | ASTM D790 | 6210 | MPa | |
| tensile strength | Break | ASTM D638 | 105 | MPa |
| elongation | Yield | ASTM D638 | 2.0to3.0 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 146 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792 | 1.29 | g/cm³ | |
| Shrinkage rate | MD:3.18mm | 0.10to0.30 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | ASTM D257 | >1.0E+7 | ohms·cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.