| flammability | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Flammability level | UL 94 | V-0 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Break | ISO 527-2 | 140 | Mpa |
| Tensile strain | Break | ISO 527-2 | 1.7 | % |
| Bending modulus | ISO 178 | 12500 | Mpa | |
| Tensile modulus | ISO 527-2 | 12500 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45 MPa, Unannealed | ISO 75-2/B | 290 | °C |
| RTI Elec | 0.75 mm | UL 746 | 65.0 | °C |
| Linear coefficient of thermal expansion | Across Flow | ISO 11359-2 | 4.5E-5 | cm/cm/°C |
| Flow | ISO 11359-2 | 3.5E-5 | cm/cm/°C | |
| Melting temperature | ISO 11357-3 | 295 | °C | |
| Hot deformation temperature | 1.8 MPa, Unannealed | ISO 75-2/A | 290 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 1.8 | % |
| Shrinkage rate | Flow | ISO 294-4 | 0.40 | % |
| 横向Flow | ISO 294-4 | 1.0 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | PLC 1 | ||
| Relative permittivity | 1.00 GHz | IEC 60250 | 3.90 | |
| 1 MHz | IEC 60250 | 4.10 | ||
| Dielectric strength | IEC 60243-1 | 33 | KV/mm | |
| Volume resistivity | IEC 60093 | > 1.0E+15 | ohms·cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.