Technical Data Sheet
optical performance | Test Condition | Test Method | Test Result |
---|
transmittance | | ISO 13468-2 | 91 % |
refractive index | | ISO 489 | 1.530 |
Basic performance | Test Condition | Test Method | Test Result |
---|
density | | ISO 1183 | 1.02 g/cm |
Water absorption rate | | ISO 62 | 0.01 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-2 | 2999 Mpa |
Tensile stress | | ISO 527-2 | 57 Mpa |
Tensile strain | | ISO 527-2 | 2.4 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric constant | | IEC 60250 | 2.35 |
dielectric constant | | IEC 60250 | 2.35 |
dielectric constant | | IEC 60250 | 2.35 |
dielectric constant | | IEC 60250 | 2.30 |
Dissipation Factor | | IEC 60250 | 0.00007 |
Volume resistivity | | IEC 60093 | 1E+16 Ω·cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | HB |
vicat | | ISO 306 | 177 °C |
Heat distortion temperature | | ISO 75B-1 | 170 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.