PC XANTAR® MX 1061 Mitsubishi Chemical Corporation
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| Filling analysis | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| ThermalConductivityofMelt | 0.24 | W/m/K | ||
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
| transmissivity | ASTM D1003 | 89.0 | % | |
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | 23°C | ISO 180/4A | 80 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Flammability level | 1.5mm | IEC 60695-11-10,-20 | V-2 | |
| 3.0mm | IEC 60695-11-10,-20 | V-2 | ||
| Burning wire flammability index | 1.5mm | IEC 60695-2-12 | 800 | °C |
| 3.0mm | IEC 60695-2-12 | 960 | °C | |
| Hot filament ignition temperature | 1.5mm | IEC 60695-2-13 | 825 | °C |
| 3.0mm | IEC 60695-2-13 | 875 | °C | |
| Extreme Oxygen Index | ISO 4589-2 | 26 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2 | 2300 | MPa | |
| tensile strength | Yield | ISO 527-2 | 60.0 | MPa |
| Tensile strain | Yield | ISO 527-2 | 6.0 | % |
| Bending modulus | ISO 178 | 2400 | MPa | |
| bending strength | ISO 178 | 90.0 | MPa | |
| Nominal tensile fracture strain | ISO 527-2 | >50 | % | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Ball Pressure Test | 125°C | IEC 60695-10-2 | 通过 | |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 6.5E-05 | cm/cm/°C |
| RTI Elec | 1.5mm | UL 746 | 130 | °C |
| 3.0mm | UL 746 | 130 | °C | |
| RTI Imp | 1.5mm | UL 746 | 125 | °C |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 130 | °C |
| Vicat softening temperature | ISO 306/B50 | 150 | °C | |
| RTI Imp | 3.0mm | UL 746 | 130 | °C |
| RTI | 1.5mm | UL 746 | 125 | °C |
| 3.0mm | UL 746 | 130 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.20 | g/cm³ | |
| Melt Volume Flow Rate (MVR) | 300°C/1.2kg | ISO 1133 | 3.00 | cm³/10min |
| Shrinkage rate | MD | ISO 294-4 | 0.60 | % |
| Water absorption rate | Saturation,23°C | ISO 62 | 0.35 | % |
| LimitingViscosity | ISO 1628-4 | 61.0 | cm³/g | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 2 | |
| Volume resistivity | IEC 60093 | >1.0E+15 | ohms·cm | |
| Compared to the anti leakage trace index | IEC 60112 | PLC 3 | ||
| Dielectric strength | IEC 60243-1 | 29 | kV/mm | |
| Relative permittivity | 100Hz | IEC 60250 | 3.00 | |
| 1MHz | IEC 60250 | 2.90 | ||
| Dissipation factor | 100Hz | IEC 60250 | 6.6E-04 | |
| 1MHz | IEC 60250 | 9.2E-03 | ||
| Surface resistivity | IEC 60093 | >1.0E+15 | ohms | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | M-Sale | ISO 2039-2 | 70 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.