Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.19 g/cm³ |
melt mass-flow rate | | ASTM D1238 | 3.7 g/10min |
Shrinkage rate | | ASTM D955 | 0.20to0.60 % |
Water absorption rate | | ASTM D570 | 0.30 % |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | M-Scale | ASTM D785 | 93 |
optical performance | Test Condition | Test Method | Test Result |
---|
refractive index | | ASTM D542 | 1.490 |
transmissivity | | ASTM D1003 | 92.0 % |
Haze ratio | | ASTM D1003 | <1.0 % |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | HB |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
ASTMClassification | | ASTM D788 | PMMA0141V3 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ASTM D638 | 3100 MPa |
tensile strength | Yield | ASTM D638 | 70.3 MPa |
elongation | Break | ASTM D638 | 6.0 % |
Flexural modulus | | ASTM D790 | 3100 MPa |
bending strength | Yield | ASTM D790 | 103 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 16 J/m |
Thermal performance | Test Condition | Test Method | Test Result |
---|
thermal conductivity | | ASTMC177 | 0.19 W/m/K |
Heat distortion temperature | | ASTM D648 | 105 °C |
Heat distortion temperature | | ASTM D648 | 102 °C |
vicat | | ASTM D15253 | 111 °C |
vicat | | ASTM D15254 | 104 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.