Share
Add to Compare

PC 2805 COVESTRO SHANGHAI

1827

Form:Granules | Grade:Injection grade

Properties:
currencyMedium viscosity
Typical Applications:
Industrial applicationsElectrical fieldElectronic fieldAutomotive sector
Product Description
Certificates(2)
Datasheet
Alternative(26)

Product Description

Typical Applications:Industrial applications | Electrical field | Electronic field | Automotive sector
Properties:currency | Medium viscosity

Certificates

UL
UL
SGS
SGS

Technical Data Sheet

optical performanceTest ConditionTest MethodTest ResultTest Unit
Transmittance rateASTM D1003/ISO 1346889%
Refractive indexASTM D542/ISO 4891.586
otherTest ConditionTest MethodTest ResultTest Unit
characteristic家用电器、照明工程
Color透明
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Charpy Notched Impact StrengthASTM D256/ISO 179Nkg·cm/cm(J/M)ft·lb/in
Impact strength of cantilever beam gapASTM D256/ISO 17990kg·cm/cm(J/M)ft·lb/in
Impact strength of cantilever beam gapASTM D256/ISO 17915kg·cm/cm(J/M)ft·lb/in
Elongation at BreakASTM D638/ISO 527>50%
Tensile modulusASTM D638/ISO 5272400kg/cm²(MPa)[Lb/in²]
elongationASTM D638/ISO 527>66%
Elongation at BreakASTM D638/ISO 527>50%
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Combustibility (rate)UL 94V-2
Hot deformation temperatureHDTASTM D648/ISO 75138℃(℉)
Hot deformation temperatureHDTASTM D648/ISO 75125℃(℉)
Vicat softening temperatureASTM D1525/ISO R306145℃(℉)
Linear coefficient of thermal expansionASTM D696/ISO 113590.65mm/mm.℃
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityASTM D792/ISO 11831.2
Shrinkage rateASTM D9550.6-0.8%
melt mass-flow rateASTM D1238/ISO 113310g/10min
Water absorption rateASTM D570/ISO 620.30%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Surface resistivityASTM D257/IEC 600931E16Ω
Dielectric constantASTM D150/IEC 602503.1
Dielectric constantASTM D150/IEC 602503.0
Arc resistanceASTM D495/IEC 60112275
Volume resistivityASTM D257/IEC 600931E14Ω.cm
Dielectric lossASTM D150/IEC 602505
Dielectric lossASTM D150/IEC 6025090
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.