Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
melt mass-flow rate | | ASTM D1238 | 14to20 g/10min |
Shrinkage rate | | ASTM D955 | 0.70 % |
Water absorption rate | | ASTM D570 | 0.37 % |
density | | ASTM D792 | 1.30 g/cm³ |
optical performance | Test Condition | Test Method | Test Result |
---|
refractive index | | ASTM D542 | 1.672 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
Limiting Oxygen Index | | ASTM D2863 | 38 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ASTM D638 | 2340 Mpa |
tensile strength | | ASTM D638 | 69.6 Mpa |
tensile strength | | ASTM D638 | 69.6 Mpa |
elongation | | ASTM D638 | 7.2 % |
elongation | | ASTM D638 | 60 % |
Flexural modulus | | ASTM D790 | 2410 Mpa |
bending strength | | ASTM D790 | 91.0 Mpa |
Compression Modulus | | ASTM D695 | 1730 Mpa |
compressive strength | | ASTM D695 | 98.9 Mpa |
shear strength | | ASTM D732 | 62.7 Mpa |
Poisson's ratio | | ASTME132 | 0.42 |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 690 J/m |
Impact strength of cantilever beam gap | | ASTM D256 | NoBreak |
Impact strength of cantilever beam gap | | ASTM D1822 | 399 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Volume resistivity | | ASTM D257 | 9E+15 ohms·cm |
dielectric strength | | ASTM D149 | 14 KV/mm |
dielectric constant | | ASTM D150 | 3.44 |
dielectric constant | | ASTM D150 | 3.40 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Hot deformation temperature (HDT) | | ASTM D648 | 214 °C |
Hot deformation temperature (HDT) | | ASTM D648 | 207 °C |
Glass Transition Temperature | | ASTME1356 | 220 °C |
| | ASTM D696 | 5.6E-05 cm/cm/°C |
thermal conductivity | | ASTMC177 | 0.35 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.