Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ISO 1183 | 1.50 g/cm³ |
Shrinkage rate | | ISO 2577 | 0.60to0.80 % |
Shrinkage rate | | ISO 2577 | 1.0to1.3 % |
Water absorption rate | | ISO 62 | <200.0 mg |
flammability | Test Condition | Test Method | Test Result |
---|
Burning wire flammability index | | IEC 707 | 960 °C |
Limiting Oxygen Index | | ASTM D2863 | >40 % |
UL flame retardant rating | | UL 94 | V-0 |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
Emission | | ISO 4614 | <3.00 mg/l |
Emission | | ISO 4614 | <3.00 mg/l |
Emission | | ISO 4614 | <3.00 mg/l |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | Yield | ISO 527-2 | >45.0 MPa |
bending strength | | ISO 178 | >80.0 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO 179/1eA | >1.1 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179/1eU | >5.0 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC 60093 | 1E+11 ohms |
dielectric constant | | DIN 53483 | 5.00 |
Dissipation Factor | | IEC 60250 | <0.10 |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | PLC 0 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2/C | >110 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.