PPA HFFR-4133 BK324 SOLVAY USA
38
Form:Granules | Grade:Injection grade
Properties:
Low warpageGlass fiber reinforcedFiller: Glass fiber reinf33% filler by weight33% filler by weight
Typical Applications:
Automotive ApplicationsLaptop caseElectrical/Electronic Applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive Applications | Laptop case | Electrical/Electronic Applications |
| Properties: | Low warpage | Glass fiber reinforced | Filler: Glass fiber reinf | 33% filler by weight | 33% filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | ISO 180/1A | 7.0to8.0 | kJ/m² | |
| Suspended wall beam without notch impact strength | ISO 180/1U | 40to48 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.40mm | UL 94 | V-0 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2 | 12000 | Mpa | |
| tensile strength | Yield | ISO 527-2 | 145to160 | Mpa |
| Tensile strain | Break | ISO 527-2 | 1.9to2.3 | % |
| Bending modulus | ISO 178 | 10800 | Mpa | |
| bending strength | ISO 178 | 220to230 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/Af | 300 | °C |
| Linear coefficient of thermal expansion | MD:0to90°C | ASTME831 | 2E-05 | cm/cm/°C |
| MD:120to200°C | ASTME831 | 1.2E-05 | cm/cm/°C | |
| TD:0to90°C | ASTME831 | 8E-05 | cm/cm/°C | |
| TD:120to200°C | ASTME831 | 1.3E-04 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183/A | 1.46 | g/cm³ | |
| Shrinkage rate | TD | ISO 294-4 | 1.3 | % |
| MD | ISO 294-4 | 0.32 | % | |
| Water absorption rate | 24hr | ASTM D570 | 0.28 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric constant | 100Hz | ASTM D150 | 3.78 | |
| 1MHz | ASTM D150 | 3.53 | ||
| Dissipation factor | 100Hz | ASTM D150 | 5E-03 | |
| 1MHz | ASTM D150 | 0.012 | ||
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 0 | |
| Volume resistivity | ASTM D257 | 1.3E+16 | ohms·cm | |
| Dielectric strength | 0.800mm | ASTM D149 | 30 | KV/mm |
| 1.60mm | ASTM D149 | 26 | KV/mm | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Scale | ASTM D785 | 121 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.