POM 570 DUPONT USA
268
Form:Granules | Grade:Enhanced level
Properties:
UV resistancewear resistantHigh temperature resistanFiller: Glass fiber reinf20%Filler by weight
Typical Applications:
household electrical appliancesFitness equipment
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | household electrical appliances | Fitness equipment |
| Properties: | UV resistance | wear resistant | High temperature resistan | Filler: Glass fiber reinf | 20% | Filler by weight |
Certificates

Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 6.0 | kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 54 | kJ/m² |
| -30°C | ISO 179/1eU | 50 | kJ/m² | |
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 3.5 | kJ/m² |
| -30°C | ISO 179/1eA | 3.0 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.5mm | IEC 60695-11-10,-20 | HB | |
| 3.0mm | UL 94 | HB | ||
| Fogging-G-value | condensate | ISO 6452 | 5E-04 | g |
| FMVSS flammability | FMVSS302 | B | ||
| UL flame retardant rating | 3.0mm | IEC 60695-11-10,-20 | HB | |
| Burning rate | 1.00mm | ISO 3795 | 53 | mm/min |
| UL flame retardant rating | 1.5mm | UL 94 | HB | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Break | ISO 527-2 | 53.0 | Mpa |
| Tensile modulus | ISO 527-2 | 4900 | Mpa | |
| Tensile strain | Break | ISO 527-2 | 12 | % |
| Bending modulus | ISO 178 | 4600 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 6E-05 | cm/cm/°C |
| Melting temperature | ISO 11357-3 | 178 | °C | |
| Vicat softening temperature | ISO 306/B50 | 160 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 125 | °C |
| 0.45MPa,Unannealed | ISO 75-2/B | 165 | °C | |
| Linear coefficient of thermal expansion | TD | ISO 11359-2 | 8.5E-05 | cm/cm/°C |
| AnnealingTemperature | 160 | °C | ||
| AnnealingTime-Optional | 30.0 | min/mm | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium,23°C,2.00mm,50%RH | ISO 62 | 0.10 | % |
| Saturation,23°C,2.00mm | ISO 62 | 0.80 | % | |
| Shrinkage rate | MD | ISO 294-4 | 1.8 | % |
| TD | ISO 294-4 | 1.2 | % | |
| Melt Volume Flow Rate (MVR) | 190°C/2.16kg | ISO 1133 | 7.00 | cm3/10min |
| density | ISO 1183 | 1.56 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | >1.0E+15 | ohms | |
| Volume resistivity | IEC 60093 | 1E+15 | ohms·cm | |
| Relative permittivity | 100Hz | IEC 60250 | 3.90 | |
| 1MHz | IEC 60250 | 3.90 | ||
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 | ||
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| EmissionofOrganicCompounds | VDA277 | 4.80 | µgC/g | |
| Emission | VDA275 | <8.00 | mg/kg |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.