Share
Add to compare

PPS AR04B-BK TORAY JAPAN

37

Form:Granules | Grade:Injection grade

Properties:
High mobilityFiller: Glass fiber reinf40% filler by weight
Typical Applications:
Electrical applications
Product Description
Certificates(1)
Datasheet

Product Description

Typical Applications:Electrical applications
Properties:High mobility | Filler: Glass fiber reinf | 40% filler by weight

Certificates

UL
UL

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch23°CISO 17935kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating0.38mmUL 94V-0
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
tensile strengthYield,23°CISO 527-2180Mpa
Tensile strainBreak,23°CISO 527-21.5%
Bending modulus23°CISO 17815200Mpa
bending strength23°CISO 178270Mpa
shear strength23°CJISK721470.0Mpa
Friction coefficient0.25
Taber abraser1000CyclesISO 935250.0mg
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A260°C
Melting temperatureISO 11357-3278°C
Linear coefficient of thermal expansionMDISO 11359-22.3E-05cm/cm/°C
Linear coefficient of thermal expansionTDISO 11359-23.1E-05cm/cm/°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Shrinkage rateTD:3.00mm2Internal Method0.80%
Shrinkage rateMD:3.00mm4Internal Method0.20%
Water absorption rate23°C,24hrISO 620.020%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Dielectric constant23°C,1MHzIEC 602503.60
Dissipation factor23°C,1MHzIEC 602502E-03
Volume resistivityIEC 600931E+16ohms·cm
Dielectric strengthIEC 60243-124KV/mm
hardnessTest ConditionTest MethodTest ResultTest Unit
Rockwell hardnessR-ScaleISO 2039-2122
Supplementary InformationTest ConditionTest MethodTest ResultTest Unit
BarFlowLength320°C,1.00mmInternal Method150mm
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.