
POK M730A HYOSUNG KOREA
175
Form:Granules
Properties:
Bottom flowhigh viscosity
Typical Applications:
Electronic appliancesAutomotive sector
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electronic appliances | Automotive sector |
| Properties: | Bottom flow | high viscosity |
Certificates
No Data...
Technical Data Sheet
| flammability | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| UL flame retardant rating | UL 94 | HB | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | 23°C | ASTM D790 | 58.8 | Mpa |
| Bending modulus | 23°C | ASTM D790 | 1420 | Mpa |
| elongation | Break,23°C | ASTM D638 | >300 | % |
| tensile strength | 23°C | ASTM D638 | 58.8 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ASTM D1525 | 220 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 105 | °C |
| 0.45MPa,Unannealed | ASTM D648 | 210 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium,23°C,60%RH | ASTM D570 | 0.45 | % |
| Shrinkage rate | MD | ASTM D955 | 1.8-2.0 | % |
| melt mass-flow rate | 255°C/2.16kg | ASTM D1238 | 3.0 | g/10min |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric strength | ASTM D149 | 17 | KV/mm | |
| Volume resistivity | ASTM D257 | 1E+15 | ohms·cm | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Scale | ASTM D785 | 105 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.