PP 9C22420 4Plas
Properties:
Filler reinforcement material glass fiber reinforcement material 20% filler by weight characteristics copolymer chemical coupling
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | reinforcement material | glass fiber reinforcement material | 20% | filler by weight characteristics | copolymer | chemical coupling |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 20 | kJ/m² |
| -30°C | ISO 180/1A | 10 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.6mm | UL 94 | HB | |
| 1.60 mm | UL 94 | HB | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | Break, 23°C | ISO 527-2/5 | 5 | % |
| tensile strength | Break, 23°C | ISO 527-2/5 | 70 | MPa |
| Tensile modulus | 23°C | ISO 527-2/5 | 4250 | MPa |
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 20 | kJ/m² |
| Tensile strain | Break,23°C | ISO 527-2/5 | 5.0 | % |
| tensile strength | Break,23°C | ISO 527-2/5 | 70.0 | MPa |
| Tensile modulus | 23°C | ISO 527-2/5 | 4250 | MPa |
| Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 10 | kJ/m² |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8 MPa, Unannealed | ISO 75-2/A | 120 | °C |
| Melting temperature | ISO 11357 | 165 | °C | |
| ISO 11357 | 165 | °C | ||
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 120 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 230°C/2.16kg | ISO 1133 | 15 | g/10min |
| density | ISO 1183 | 1.03 | g/cm³ | |
| melt mass-flow rate | 230°C/2.16 kg | ISO 1133 | 15 | g/10 min |
| density | ISO 1183 | 1.03 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | 1E+15 | ohms | |
| Volume resistivity | IEC 60093 | 1E+15 | ohms·cm | |
| Surface resistivity | IEC 60093 | 1E+15 | ohms | |
| Volume resistivity | IEC 60093 | 1E+15 | ohms·cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.