PA+Olefin NEALID XG400 AD MAJORIS FRANCE
0
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Charpy Notched Impact Strength | ISO 179 | 12 kJ/m² | |
| Impact strength of simply supported beam without notch | ISO 179 | 36 kJ/m² |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | 1.6mm | UL 94 | HB |
| Burning wire flammability index | 2.0mm | IEC 60695-2-12 | 650 °C |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Tensile strain | Break | ISO 527-2 | 2.0 % |
| Bending modulus | ISO 178 | 9550 MPa | |
| bending strength | ISO 178 | 200 MPa | |
| Tensile modulus | ISO 527-2 | 11000 MPa | |
| tensile strength | Break | ISO 527-2 | 125 MPa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 246 °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 230 °C | |
| Melting temperature | ISO 3146 | 256 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| density | ISO 1183 | 1.36 g/cm³ | |
| Shrinkage rate | 0.30to0.60 % | ||
| Water absorption rate | Equilibrium,23°C,50%RH | 0.90 % |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Surface resistivity | DIN 53482 | 1E+15 ohms | |
| Volume resistivity | DIN 53482 | 1E+15 ohms·cm | |
| Compared to the anti leakage trace index | SolutionA | IEC 60112 | PLC 0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.