Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ISO 294-4 | 1.6 % |
Shrinkage rate | | ISO 294-4 | 1.8 % |
Water absorption rate | | ISO 62 | 1.2 % |
Water absorption rate | | ISO 62 | 2.3 % |
Outdoor applicability | | UL 746C | f1 |
density | | ISO 1183 | 1.10 g/cm³ |
flammability | Test Condition | Test Method | Test Result |
---|
Hot filament ignition temperature | | IEC 60695-2-13 | 725 °C |
Hot filament ignition temperature | | IEC 60695-2-13 | 800 °C |
Hot filament ignition temperature | | IEC 60695-2-13 | 725 °C |
Burning wire flammability index | | IEC 60695-2-12 | 700 °C |
Burning wire flammability index | | IEC 60695-2-12 | 775 °C |
Burning wire flammability index | | IEC 60695-2-12 | 700 °C |
UL flame retardant rating | | UL 94 | HB |
UL flame retardant rating | | UL 94 | HB |
UL flame retardant rating | | UL 94 | HB |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
Automotive Materials | | FMVSS302 | + |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ISO 180 | 12 kJ/m² |
Impact strength of cantilever beam gap | | ISO 180 | 16 kJ/m² |
Charpy Notched Impact Strength | | ISO 179/1eA | 11 kJ/m² |
Charpy Notched Impact Strength | | ISO 179/1eA | 17 kJ/m² |
Charpy Notched Impact Strength | | ISO 179/1eA | 19 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179/1eU | NoBreak |
Impact strength of simply supported beam without notch | | ISO 179/1eU | NoBreak |
Impact strength of cantilever beam gap | | ISO 180 | 18 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-2 | 2780 MPa |
tensile strength | | ISO 527-2 | 60.0 MPa |
bending strength | | ISO 178 | 70.0 MPa |
tensile strength | | ISO 527-2 | 52.0 MPa |
Tensile strain | | ISO 527-2 | 22 % |
Flexural modulus | | ISO 178 | 2300 MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
arc resistance | | ASTM D495 | PLC6 |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | PLC 1 |
High arc combustion index (HAI) | | UL 746 | PLC 0 |
High arc combustion index (HAI) | | UL 746 | PLC 0 |
High arc combustion index (HAI) | | UL 746 | PLC 0 |
High Voltage Arc Traceability Rate (HVTR) | | UL 746 | PLC 2 |
Hot wire ignition (HWI) | | UL 746 | PLC 4 |
Hot wire ignition (HWI) | | UL 746 | PLC 4 |
Hot wire ignition (HWI) | | UL 746 | PLC 3 |
Volume resistivity | | IEC 60093 | 1E+11 ohms·cm |
dielectric strength | | IEC 60243 | 12 kV/mm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
RTI Imp | | UL 746 | 75.0 °C |
RTI Imp | | UL 746 | 75.0 °C |
Hot deformation temperature (HDT) | | ISO 75-2/A | 63.0 °C |
melting temperature | | ISO 11357-3 | 260 °C |
| | ISO 11359-2 | 1.1E-04 cm/cm/°C |
| | ISO 11359-2 | 1.4E-04 cm/cm/°C |
RTI Elec | | UL 746 | 130 °C |
RTI Elec | | UL 746 | 130 °C |
RTI Elec | | UL 746 | 130 °C |
RTI Imp | | UL 746 | 75.0 °C |
Hot deformation temperature (HDT) | | ISO 75-2/B | 185 °C |
RTI Str | | UL 746 | 115 °C |
RTI Str | | UL 746 | 115 °C |
RTI Str | | UL 746 | 115 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.