impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch23°CISO 17960kJ/m²
Charpy Notched Impact Strength23°CISO 17911kJ/m²
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Bending modulusISO 17812000MPa
Tensile strainBreakISO 527-21.0%
tensile strengthBreakISO 527-2130MPa
Tensile modulusISO 527-213000MPa
bending strengthISO 178195MPa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Linear coefficient of thermal expansionTD:50to120°CISO 11359-21.1E-04cm/cm/°C
Linear coefficient of thermal expansionTD:-30to120°CISO 11359-29E-05cm/cm/°C
Linear coefficient of thermal expansionTD:-30to50°CISO 11359-27E-05cm/cm/°C
Linear coefficient of thermal expansionMD:50to120°CISO 11359-21E-05cm/cm/°C
Linear coefficient of thermal expansionMD:-30to120°CISO 11359-21E-05cm/cm/°C
Linear coefficient of thermal expansionMD:-30to50°CISO 11359-21E-05cm/cm/°C
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B218°C
Melting temperatureISO 11357-3224°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A190°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Shrinkage rate吸水率(Saturation,23°C)0.080%
Shrinkage rateMD:2.00mm0.30%
Shrinkage rateTD:2.00mm0.60%
densityISO 11831.53g/cm³
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Dissipation factor1MHzIEC 602500.017
Relative permittivity1MHzIEC 602503.20
Dielectric strength2.00mmIEC 60243-130kV/mm
Dielectric strength1.00mmIEC 60243-140kV/mm
Volume resistivityIEC 600931E+16ohms·cm
Surface resistivityIEC 600931E+16ohms
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.