Product Description
Certificates(1)
Datasheet
Product Description
| Properties: | Good strength |
Certificates

Technical Data Sheet
| other | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| gloss | 60° | ASTM D523 | 48 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | 23℃ | ASTM D638 | 1650 | Mpa |
| Charpy Notched Impact Strength | 23℃ | ASTM D256 | 260 | J/m |
| -40℃ | ASTM D256 | 51 | J/m | |
| bending strength | 23℃ | ASTM D790 | 47.0 | Mpa |
| Bending modulus | 23℃ | ASTM D790 | 1660 | Mpa |
| elongation | Yield, 23℃ | ASTM D638 | 2.7 | % |
| tensile strength | Yield, 23℃ | ASTM D638 | 33.0 | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8 MPa, Unannealed | ASTM D648 | 83.0 | °C |
| 0.45 MPa, Unannealed | ASTM D648 | 101 | °C | |
| Linear coefficient of thermal expansion | Flow | ISO 11359-2 | 0.000095 | cm/cm/℃ |
| Vicat softening temperature | ASTM D15253 | 92.0 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Saturation, 23℃ | ASTM D570 | 1.7 | % |
| Shrinkage rate | MD | ASTM D955 | 0.55 | % |
| Melt Volume Flow Rate (MVR) | MVR 220°C/10.0 kg | ASTM D1238 | 4.00 | cm3/10min |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric strength | IEC 60243-1 | 35 | KV/mm | |
| Dissipation factor | 1 MHz | IEC 60250 | 0.034 | |
| 100 Hz | IEC 60250 | 0.0090 | ||
| Dielectric constant | 1 MHz | IEC 60250 | 3.40 | |
| 100 Hz | IEC 60250 | 3.80 | ||
| 1.00 mm, 1 MHz | ASTM D150 | 3.40 | ||
| Volume resistivity | ASTM D257 | >1.0E+14 | ohm·cm | |
| Surface resistivity | ASTM D257 | >1.0E+13 | Ohm | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R -Sale | ASTM D785 | 89 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.