PP Homopolymer POLYFORT® FPP 20/10 TGF A SCHULMAN USA
Properties:
Filler glass mineral 20% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass mineral | 20% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 6.0 | kJ/m² |
| -30°C | ISO 179/1eA | 4.0 | kJ/m² | |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 32 | kJ/m² |
| -30°C | ISO 179/1eU | 4.0 | kJ/m² | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Break,23°C | ISO 527-2/1A/5 | 48.0 | MPa |
| Tensile modulus | ISO 527-2/1A/1 | 3900 | MPa | |
| Tensile strain | Break,23°C | ISO 527-2/1A/5 | 2.8 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | -- | ISO 306/B50 | 110 | °C |
| -- | ISO 306/A50 | 159 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Melt Volume Flow Rate (MVR) | 230°C/2.16kg | ISO 1133 | 6.00 | cm³/10min |
| density | ISO 1183/A | 1.03 | g/cm³ | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Ball Pressure Test | H358/30 | ISO 2039-1 | 98.0 | MPa |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.