PP 9D12430 FR3HUV 4Plas

Properties:
Filler glass fiber reinforced material 30% filler by weight
Product Description
Certificates(0)
Datasheet

Product Description

Properties:Filler | glass fiber reinforced material | 30% | filler by weight

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of cantilever beam gap23°CISO 180/1A10kJ/m²
Impact strength of cantilever beam gap-30°CISO 180/1A8.0kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating1.6mmUL 94V-2
UL flame retardant rating3.2mmUL 94V-2
UL flame retardant rating1.60 mmUL 94V-2
UL flame retardant rating3.20 mmUL 94V-2
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulus23°CISO 527-2/57500MPa
tensile strengthBreak, 23°CISO 527-2/580.0MPa
Tensile strainBreak, 23°CISO 527-2/53.0%
Impact strength of cantilever beam gap-30°CISO 180/1A8.0kJ/m²
Impact strength of cantilever beam gap23°CISO 180/1A10.0kJ/m²
Tensile modulus23°CISO 527-2/57500MPa
tensile strengthBreak,23°CISO 527-2/580.0MPa
Tensile strainBreak,23°CISO 527-2/53.0%
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A150°C
Melting temperatureISO 11357170°C
Hot deformation temperature0.45 MPa, UnannealedISO 75-2/B160°C
Hot deformation temperature1.8 MPa, UnannealedISO 75-2/A150°C
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B160°C
Melting temperatureISO 11357170°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityISO 11831.16g/cm³
melt mass-flow rate230°C/2.16 kgISO 11335.0g/10 min
densityISO 11831.16g/cm³
melt mass-flow rate230°C/2.16kgISO 11335.0g/10min
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Surface resistivityIEC 600931E+15ohms
Volume resistivityIEC 600931E+15ohms·cm
Volume resistivityIEC 600931E+15ohms·cm
Surface resistivityIEC 600931E+15ohms
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.