PA6 Lumid® GP2259AFL

0
  • Properties:
    Filler
    glass fiber reinforced material
    25%
    filler by weight
  • Usages:
    Switch
    electrical
    electronic application fields

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityASTMD7921.60 g/cm³
Shrinkage rateASTMD9550.40to0.90 %
Water absorption rateEquilibriumASTMD5700.70 %
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessR-ScaleASTMD785121
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL94V-2
UL flame retardant ratingUL94V-2
Mechanical propertiesTest ConditionTest MethodTest Result
Flexural StrengthASTMD790196 MPa
tensile strength ASTMD638127 MPa
elongationASTMD6384.0 %
Flexural modulusASTMD7908530 MPa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapASTMD25698 J/m
Electrical performanceTest ConditionTest MethodTest Result
dielectric strengthASTMD14921 kV/mm
dielectric constantASTMD1503.80
arc resistanceASTMD49590.0 sec
CTIIEC60112250 V
Volume resistivityASTMD2571E+15 ohms·cm
Thermal performanceTest ConditionTest MethodTest Result
ASTMD3418220 °C
ASTMD648210 °C
ASTMD6964.1E-05 cm/cm/°C
RTI ImpUL74690.0 °C
RTI ImpUL74690.0 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.