Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
transmittance | | ASTM D-1003 | 88 % |
other | Test Condition | Test Method | Test Result |
---|
characteristic | | | 注塑级 |
purpose | | | 电器 电子元件 医疗用品 灯罩 容器 |
optical performance | Test Condition | Test Method | Test Result |
---|
transmittance | | ASTM D1003/ISO 13468 | 88 % |
processability | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ASTM D-955 | 0.5-0.7 % |
Shrinkage rate | | ASTM D-955 | 0.5-0.7 % |
Basic performance | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ASTM D-570 | 0.20 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ASTM D638/ISO 527 | 2130 kg/cm²(MPa)[Lb/in²] |
elongation | | ASTM D638/ISO 527 | 6 % |
Rockwell hardness | | ASTM D785 | 77 |
bending strength | | ASTM D790/ISO 178 | 90 kg/cm²(MPa)[Lb/in²] |
elongation at break | | ASTM D638/ISO 527 | 140 % |
refractive index | | ASTM D-542 | 1.585 |
Tensile modulus | | ASTM D-638 | 2130(21700) MPa(Kgf/cm |
compressive strength | | ASTM D-695 | 76(780) MPa(Kgf/cm |
tensile strength | | ASTM D-638 | 62(630) MPa(Kgf/cm |
tensile strength | | ASTM D-638 | 78(800) MPa(Kgf/cm |
Impact strength of cantilever beam gap | | ASTM D-256 | 130(13) j/m(kgf.cm/cm) |
bending strength | | ASTM D-790 | 90(920) MPa(Kgf/cm |
Impact strength of cantilever beam gap | | ASTM D-256 | 830(85) j/m(kgf.cm/cm) |
Flexural modulus | | ASTM D-790 | 2260(23000) MPa(Kgf/cm |
Rockwell hardness | | ASTM D-785 | 77 M标度 |
elongation at break | | ASTM D-638 | 6 - |
elongation at break | | ASTM D-638 | 140 - |
Electrical performance | Test Condition | Test Method | Test Result |
---|
arc resistance | | ASTM D495/IEC 60112 | 110 |
Dielectric loss | | ASTM D-150 | 0.0004(0.009) |
arc resistance | | ASTM D-495 | 110 sec |
dielectric strength | | ASTM D-149 | 30 KV/mm |
dielectric constant | | ASTM D-150 | 2.95(2.9) |
Volume resistivity | | ASTM D-257 | 3 |
Conductive Track Resistance (CTI) | | IEC 112 | 300 V |
Physical properties | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792/ISO 1183 | 1.2 |
Water absorption rate | | ASTM D570/ISO 62 | 0.2 % |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Linear coefficient of thermal expansion | | ASTM D696/ISO 11359 | 7 mm/mm.℃ |
Linear coefficient of thermal expansion | | ASTM D-696 | 7 |
Heat distortion temperature | | ASTM D-648 | 142 °C |
TEMPERATURE | | UL 746B | 125 °C |
TEMPERATURE | | UL 746B | 115 °C |
TEMPERATURE | | UL 746B | 125 °C |
Heat distortion temperature | | ASTM D-648 | 132 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.