PP Copolymer POLYFORT® FIPP 10 T A SCHULMAN USA
Properties:
Filler talc filler 10% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | talc filler | 10% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 66 | kJ/m² |
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 9.0 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Burning rate | ISO 3795 | <100 | mm/min | |
| Burning wire flammability index | IEC 60695-2-12 | 750 | °C | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2/1A/1 | 1300 | MPa | |
| tensile strength | Yield | ISO 527-2/1A/50 | 19.0 | MPa |
| Tensile strain | Yield | ISO 527-2/1A/50 | 6.0 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/Bf | 87.0 | °C |
| 1.8MPa,Unannealed | ISO 75-2/Af | 50.0 | °C | |
| Vicat softening temperature | -- | ISO 306/A50 | 132 | °C |
| -- | ISO 306/B50 | 54.0 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183/A | 1.00 | g/cm³ | |
| Melt Volume Flow Rate (MVR) | 230°C/2.16kg | ISO 1133 | 30.0 | cm³/10min |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | >1.0E+15 | ohms | |
| Volume resistivity | IEC 60093 | >1.0E+13 | ohms·cm | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Ball Pressure Test | H358/30 | ISO 2039-1 | 73.0 | MPa |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.