Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PPS 1140L4 SF3001 CELANESE USA
FORTRON®
Fiber grade,During injection molding,Slight flash
Flame retardant,High temperature resistan,enhance,Glass fiber reinforced,Injection grade,Medium melt viscosity
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
hardness | Test Condition | Test Method | CELANESE USA/1140L4 SF3001 |
---|---|---|---|
Rockwell hardness | M-Sale | ISO 2039-2 | 100 |
M-Scale | ASTM D785 | 100 |
Supplementary Information | Test Condition | Test Method | CELANESE USA/1140L4 SF3001 |
---|---|---|---|
Shrinkage rate | Internal Method | 3.18 mm |
Basic Performance | Test Condition | Test Method | CELANESE USA/1140L4 SF3001 |
---|---|---|---|
density | ISO 1183 | 1.65 g/cm³ | |
Water absorption rate | ASTM-D570 | 0.02 % |
thermal performance | Test Condition | Test Method | CELANESE USA/1140L4 SF3001 |
---|---|---|---|
Glass transition temperature | ISO 11357-2 | 90.0 °C | |
Hot deformation temperature | 0.45MPa,Annealed | ASTM D648 | 280 °C |
1.8MPa,Unannealed | ASTM D648 | 265 °C | |
8.0MPa,Unannealed | ISO 75-2/C | 215 °C | |
1.8MPa,Unannealed | ISO 75-2/A | 270 °C | |
1.80Mpa | ISO 75-A | 270 °C | |
Linear coefficient of thermal expansion | TD | ISO 11359-2 | 4.2E-05 cm/cm/°C |
MD | ISO 11359-2 | 2.6E-05 cm/cm/°C | |
Melting temperature | ISO 11357-3 | 280 °C | |
UL flame retardant rating | UL 94 | V-0 |
mechanical properties | Test Condition | Test Method | CELANESE USA/1140L4 SF3001 |
---|---|---|---|
Bending modulus | ISO 178 | 14500 Mpa | |
23°C | ISO 178 | 14500 Mpa | |
bending strength | ISO 178 | 285 Mpa | |
elongation | Break | ISO 527-2/1A/5 | 1.9 % |
Break,23°C | ASTM D638 | 1.7 % | |
Impact strength of cantilever beam gap | ISO 180/1A | 10 kJ/m² | |
Rockwell hardness | ASTM-D785 | 100 R-Scale | |
Tensile modulus | 75°C | ASTM D638 | 11900 Mpa |
-40°C | ASTM D638 | 14500 Mpa | |
-- | ISO 527-2/1A/1 | 14700 Mpa | |
150°C | ASTM D638 | 4270 Mpa | |
200°C | ASTM D638 | 3240 Mpa | |
ISO 527 | 14700 Mpa | ||
tensile strength | ISO 527 | 195 Mpa | |
Break,23°C | ASTM D638 | 200 Mpa | |
Break | ISO 527-2/1A/5 | 195 Mpa |
Electrical performance | Test Condition | Test Method | CELANESE USA/1140L4 SF3001 |
---|---|---|---|
Arc resistance | ASTM D495 | 134 sec | |
Compared to the anti leakage trace index | IEC 60112 | PLC 4 | |
Dielectric constant | 1MHz | ASTM D150 | 3.50 |
1kHz | ASTM D150 | 3.50 | |
1MHz | IEC 60250 | 4.60 | |
Dielectric strength | IEC 60243-1 | 28 KV/mm | |
Dissipation factor | 1MHz | IEC 60250 | 6.2E-03 |
1MHz | ASTM D150 | 1E-03 | |
1kHz | ASTM D150 | 1E-03 | |
Surface resistivity | IEC 60093 | >1.0E+15 ohms | |
Volume resistivity | -- | ASTM D257 | 1E+16 ohms·cm |
-- | IEC 60093 | >1.0E+15 ohms·cm |
Physical properties | Test Condition | Test Method | CELANESE USA/1140L4 SF3001 |
---|---|---|---|
density | ASTMD792 | 1.65 g/cm³ | |
Shrinkage rate | MD | ISO 294-4 | 0.20-0.60 % |
ISO 294-4 | 0.2-0.6 % | ||
MD | ASTM D955 | 0.20-0.30 % | |
TD | ISO 294-4 | 0.40-0.60 % | |
TD | ASTM D955 | 0.50-0.70 % | |
Specific volume | ASTM D792 | 0.611 cm³/g | |
Water absorption rate | Saturation,23°C | ISO 62 | 0.020 % |
Biochemical properties | Test Condition | Test Method | CELANESE USA/1140L4 SF3001 |
---|---|---|---|
Filling amount | 40 % |
impact performance | Test Condition | Test Method | CELANESE USA/1140L4 SF3001 |
---|---|---|---|
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 10 kJ/m² |
-30°C | ISO 179/1eA | 10 kJ/m² | |
Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 10 kJ/m² |
23°C | ISO 180/1A | 10 kJ/m² | |
Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 53 kJ/m² |
23°C | ISO 179/1eU | 53 kJ/m² | |
Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 34 kJ/m² |
flammability | Test Condition | Test Method | CELANESE USA/1140L4 SF3001 |
---|---|---|---|
Extreme Oxygen Index | ISO 4589-2 | 47 % | |
UL flame retardant rating | 3.0mm | UL 94 | 5VA |
0.38mm | UL 94 | V-0 | |
1.5mm | UL 94 | V-0 |
Filling analysis | Test Condition | Test Method | CELANESE USA/1140L4 SF3001 |
---|---|---|---|
SpecificHeatCapacity of Melt | Internal Method | 1500 J/kg/°C |