Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA12 Grilamid® L 25 Z EMS-GRIVORY
--
Industrial applications, hydraulic applications, automotive applications, consumer goods applications, pneumatic applications, electrical and electronic applications, pipe fittings, wire and cable applications
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| hardness | Test Condition | Test Method | EMS-GRIVORY/Grilamid® L 25 Z |
|---|---|---|---|
| Ball Pressure Test | MPa | 55.0 -- | |
| Shore hardness | ShoreD,15Sec | 68 -- |
| thermal performance | Test Condition | Test Method | EMS-GRIVORY/Grilamid® L 25 Z |
|---|---|---|---|
| Continuous use temperature | --2 | °C | 90.0to110 -- |
| --3 | °C | 140 -- | |
| Hot deformation temperature | 0.45MPa,Unannealed | °C | 85.0 -- |
| 1.8MPa,Unannealed | °C | 40.0 -- | |
| Linear coefficient of thermal expansion | TD | cm/cm/°C | 1.4E-04 -- |
| MD | cm/cm/°C | 1.2E-04 -- | |
| Melting temperature | °C | 179 -- |
| mechanical properties | Test Condition | Test Method | EMS-GRIVORY/Grilamid® L 25 Z |
|---|---|---|---|
| Nominal tensile fracture strain | % | >50 -- | |
| Tensile modulus | MPa | 900 -- | |
| Tensile strain | Yield | % | 12 -- |
| Break | % | >50 -- | |
| tensile strength | Yield | MPa | 35.0 -- |
| Break | MPa | 40.0 40.0 |
| Electrical performance | Test Condition | Test Method | EMS-GRIVORY/Grilamid® L 25 Z |
|---|---|---|---|
| Compared to the anti leakage trace index | V | -- | |
| Dielectric strength | kV/mm | 22 -- | |
| Surface resistivity | ohms | -- 1E+12 | |
| Volume resistivity | ohms·cm | -- 1E+13 |
| Physical properties | Test Condition | Test Method | EMS-GRIVORY/Grilamid® L 25 Z |
|---|---|---|---|
| density | g/cm³ | 1.00 -- | |
| Shrinkage rate | TD | % | 1.3 -- |
| MD | % | 0.80 -- | |
| Water absorption rate | Saturation,23°C | % | 1.5 -- |
| Equilibrium,23°C,50%RH | % | 0.70 -- |
| impact performance | Test Condition | Test Method | EMS-GRIVORY/Grilamid® L 25 Z |
|---|---|---|---|
| Charpy Notched Impact Strength | -30°C | kJ/m² | 13 -- |
| 23°C | kJ/m² | 55 -- | |
| Impact strength of simply supported beam without notch | -30°C | 无断裂 | |
| 23°C | 无断裂 |
| flammability | Test Condition | Test Method | EMS-GRIVORY/Grilamid® L 25 Z |
|---|---|---|---|
| Flammability level | 0.8mm | HB -- |