| thermal performance | Test Condition | Test Method | JILIN JOINATURE/330G |
|---|---|---|---|
| Hot deformation temperature | 1.8 Mpa | ISO 75-f | 156 °C |
| Linear coefficient of thermal expansion | 低于Tg沿着Flow | ISO 11359 | 50 ppm/K |
| 高于Tg沿着Flow | ISO 11359 | 120 ppm/K | |
| Melting temperature | Tg(起始) | ISO 11357 | 143 °C |
| specific heat | 23℃ | DSC | 2.2 kJ/kg /℃ |
| thermal conductivity | 23℃ | ISO 22007-4 | 0.29 W/m/K |
| mechanical properties | Test Condition | Test Method | JILIN JOINATURE/330G |
|---|---|---|---|
| Bending modulus | 23℃ | ISO 178 | 4300 Mpa |
| bending strength | Yield,23℃ | ISO 178 | 175 Mpa |
| compressive strength | 23℃ | ISO 604 | 130 Mpa |
| Shore hardness | 23℃ | ISO 868 | 85 D 级 |
| Tensile strain | Break,23℃ | ISO 527 | 25 % |
| tensile strength | Yield,23℃ | ISO 527 | 110 Mpa |
| Electrical performance | Test Condition | Test Method | JILIN JOINATURE/330G |
|---|---|---|---|
| Compared to the anti leakage trace index | IEC 60112 | PLC 4 | |
| Dielectric constant | 23 ℃, 1 kHz | IEC 60250 | 3.2 |
| Dielectric strength | 2 mm | IEC 60243-1 | 23 KV/mm |
| Dissipation factor | 23℃,1 MHz | IEC 60250 | 0.004 |
| Volume resistivity | 23 ℃,1V | IEC 60093 | 10^16 ohms·cm |
| 275 ℃ | IEC 60093 | 10^9 ohms·cm |
| Physical properties | Test Condition | Test Method | JILIN JOINATURE/330G |
|---|---|---|---|
| density | 非结晶 | ISO 1183 | 1.26 g/cm³ |
| 结晶 | ISO 1183 | 1.3 g/cm³ | |
| melt mass-flow rate | 380℃,5.0kg | ISO 1133 | 80 g/10min |
| Shrinkage rate | MD | ISO 294-4 | 1.3 % |
| TD | ISO 294-4 | 1 % | |
| Water absorption rate | 23℃,24hr,3.2 mm厚拉伸棒 | ISO 62-1 | 0.07 % |
| Equilibrium,23℃ | ISO 62-1 | 0.4 % |
| impact performance | Test Condition | Test Method | JILIN JOINATURE/330G |
|---|---|---|---|
| Charpy Notched Impact Strength | ISO 179-1eA | 4 kJ/m² | |
| Impact strength of cantilever beam gap | ISO 180/A | 5 kJ/m² | |
| Impact strength of simply supported beam without notch | ISO 179/1U | - kJ/m² | |
| Suspended wall beam without notch impact strength | ISO 180/U | - kJ/m² |