Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

ASA 757R BK BASF GERMANY
Luran®S
doors and windows,Household goods
--
UL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
hardness | Test Condition | Test Method | BASF GERMANY/757R BK |
---|---|---|---|
Ball Pressure Test | ISO 2039-1 | 100 Mpa |
thermal performance | Test Condition | Test Method | BASF GERMANY/757R BK |
---|---|---|---|
Hot deformation temperature | 1.8MPa,Annealed | ISO 75-2/A | 97.0 °C |
0.45MPa,Annealed | ISO 75-2/B | 101 °C | |
Linear coefficient of thermal expansion | MD | ISO 11359-2 | 8.0E-5到1.1E-4 cm/cm/°C |
thermal conductivity | DIN 52612 | 0.17 W/m/K | |
Vicat softening temperature | -- | ISO 306/B50 | 98.0 °C |
-- | ISO 306/A50 | 105 °C |
mechanical properties | Test Condition | Test Method | BASF GERMANY/757R BK |
---|---|---|---|
bending strength | ISO 178 | 80.0 Mpa | |
Tensile creep modulus | 1000hr | ISO 899-1 | 1400 Mpa |
Tensile modulus | ISO 527-2 | 2600 Mpa | |
Tensile strain | Yield,23°C | ISO 527-2 | 3.1 % |
tensile strength | Yield,23°C | ISO 527-2 | 56.0 Mpa |
Electrical performance | Test Condition | Test Method | BASF GERMANY/757R BK |
---|---|---|---|
Dielectric constant | 100Hz | IEC 60250 | 3.70 |
1.00mm,1MHz | IEC 60250 | 3.40 | |
Dissipation factor | 1MHz | IEC 60250 | 0.025 |
100Hz | IEC 60250 | 9E-03 | |
Surface resistivity | IEC 60093 | 1E+13 ohms | |
Volume resistivity | IEC 60093 | 1E+14 ohms·cm |
Physical properties | Test Condition | Test Method | BASF GERMANY/757R BK |
---|---|---|---|
density | ISO 1183 | 1.07 g/cm³ | |
Melt Volume Flow Rate (MVR) | 220°C/10.0kg | ISO 1133 | 8.00 cm3/10min |
Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.35 % |
Saturation,23°C | ISO 62 | 1.7 % |
impact performance | Test Condition | Test Method | BASF GERMANY/757R BK |
---|---|---|---|
Charpy Notched Impact Strength | -30°C | ISO 179 | 3.0 kJ/m² |
23°C | ISO 179 | 12 kJ/m² | |
Impact strength of cantilever beam gap | -30°C | ISO 180/A | 3.0 kJ/m² |
23°C | ISO 180/A | 13 kJ/m² |