Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PBT 5010N6 BK MITSUBISHI ENGINEERING JAPAN
NOVADURAN™
Bottle cap,Automotive Applications
Flame retardant
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
thermal performance | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/5010N6 BK |
---|---|---|---|
Hot deformation temperature | 1.8 MPa, Annealed | ISO 75-2/A | 77.0 °C |
0.45 MPa, Annealed | ISO 75-2/B | 165 °C | |
Linear coefficient of thermal expansion | Flow : 35 to 120°C | ISO 11359-2 | 1.4E-4 cm/cm/°C |
Flow : -30 to 120°C | ISO 11359-2 | 1.2E-4 cm/cm/°C | |
Across Flow : -30 to 120°C | ISO 11359-2 | 1.2E-4 cm/cm/°C | |
Across Flow : 35 to 120°C | ISO 11359-2 | 1.5E-4 cm/cm/°C | |
Across Flow : -30 to 35°C | ISO 11359-2 | 8.8E-5 cm/cm/°C | |
Flow : -30 to 35°C | ISO 11359-2 | 8.0E-5 cm/cm/°C | |
Melting temperature | ISO 11357-3 | 224 °C | |
RTI | 0.71 mm | UL 746 | 140 °C |
RTI Elec | 0.71 mm | UL 746 | 140 °C |
RTI Imp | 0.71 mm | UL 746 | 120 °C |
mechanical properties | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/5010N6 BK |
---|---|---|---|
Bending modulus | ISO 178 | 2600 Mpa | |
bending strength | ISO 178 | 90.0 Mpa | |
Tensile modulus | ISO 527-2/1 | 2800 Mpa | |
Tensile strain | Break | ISO 527-2/50 | 50 % |
Yield | ISO 527-2/50 | 4.3 % | |
tensile strength | Yield | ISO 527-2/50 | 55.0 Mpa |
Electrical performance | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/5010N6 BK |
---|---|---|---|
Compared to the anti leakage trace index | UL 746 | PLC 1 | |
Dielectric constant | 1 MHz | IEC 60250 | 3.20 |
Dielectric strength | 1.00 mm | IEC 60243-1 | 21 KV/mm |
2.00 mm | IEC 60243-1 | 18 KV/mm | |
Dissipation factor | 1 MHz | IEC 60250 | 0.020 |
Surface resistivity | IEC 60093 | 1.0E+15 ohms | |
Volume resistivity | IEC 60093 | 1.0E+16 ohms·cm |
Physical properties | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/5010N6 BK |
---|---|---|---|
Melt Volume Flow Rate (MVR) | 250°C/2.16 kg | ISO 1133 | 20.0 cm3/10min |
Shrinkage rate | Flow : 2.00 mm | Internal Method | 1.9 % |
横向Flow : 2.00 mm | Internal Method | 1.8 % | |
Water absorption rate | Saturation, 23°C | ISO 62 | 0.080 % |
impact performance | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/5010N6 BK |
---|---|---|---|
Impact strength of simply supported beam without notch | 23°C | ISO 179 | 120 kJ/m² |
flammability | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/5010N6 BK |
---|---|---|---|
UL flame retardant rating | 0.71 mm | UL 94 | V-0 |
3.2 mm | UL 94 | V-0 | |
1.6 mm | UL 94 | V-0 |
injection | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/5010N6 BK |
---|---|---|---|
Drying Temperature - Vacuum Drying Machine | 120 °C | ||
Drying time - vacuum dryer | 5.0 to 8.0 hr | ||
Injection pressure | 20.0 to 150 Mpa | ||
Injection speed | 中等偏快 | ||
Mold temperature | 60 to 80 °C | ||
Screw speed | 80 to 120 rpm | ||
Spray nozzle temperature | 245 °C | ||
Temperature at the front of the material cylinder | 250 °C | ||
Temperature at the rear of the barrel | 235 °C | ||
Temperature in the middle of the barrel | 240 °C |