plas

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PBT 5010N6 BK MITSUBISHI ENGINEERING JAPAN
NOVADURAN™ 
Bottle cap,Automotive Applications
Flame retardant
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

thermal performanceTest ConditionTest MethodMITSUBISHI ENGINEERING JAPAN/5010N6 BK
Hot deformation temperature1.8 MPa, AnnealedISO 75-2/A77.0 °C
0.45 MPa, AnnealedISO 75-2/B165 °C
Linear coefficient of thermal expansionFlow : 35 to 120°CISO 11359-21.4E-4 cm/cm/°C
Flow : -30 to 120°CISO 11359-21.2E-4 cm/cm/°C
Across Flow : -30 to 120°CISO 11359-21.2E-4 cm/cm/°C
Across Flow : 35 to 120°CISO 11359-21.5E-4 cm/cm/°C
Across Flow : -30 to 35°CISO 11359-28.8E-5 cm/cm/°C
Flow : -30 to 35°CISO 11359-28.0E-5 cm/cm/°C
Melting temperatureISO 11357-3224 °C
RTI0.71 mmUL 746140 °C
RTI Elec0.71 mmUL 746140 °C
RTI Imp0.71 mmUL 746120 °C
mechanical propertiesTest ConditionTest MethodMITSUBISHI ENGINEERING JAPAN/5010N6 BK
Bending modulusISO 1782600 Mpa
bending strengthISO 17890.0 Mpa
Tensile modulusISO 527-2/12800 Mpa
Tensile strainBreakISO 527-2/5050 %
YieldISO 527-2/504.3 %
tensile strengthYieldISO 527-2/5055.0 Mpa
Electrical performanceTest ConditionTest MethodMITSUBISHI ENGINEERING JAPAN/5010N6 BK
Compared to the anti leakage trace indexUL 746PLC 1
Dielectric constant1 MHzIEC 602503.20
Dielectric strength1.00 mmIEC 60243-121 KV/mm
2.00 mmIEC 60243-118 KV/mm
Dissipation factor1 MHzIEC 602500.020
Surface resistivityIEC 600931.0E+15 ohms
Volume resistivityIEC 600931.0E+16 ohms·cm
Physical propertiesTest ConditionTest MethodMITSUBISHI ENGINEERING JAPAN/5010N6 BK
Melt Volume Flow Rate (MVR)250°C/2.16 kgISO 113320.0 cm3/10min
Shrinkage rateFlow : 2.00 mmInternal Method1.9 %
横向Flow : 2.00 mmInternal Method1.8 %
Water absorption rateSaturation, 23°CISO 620.080 %
impact performanceTest ConditionTest MethodMITSUBISHI ENGINEERING JAPAN/5010N6 BK
Impact strength of simply supported beam without notch23°CISO 179120 kJ/m²
flammabilityTest ConditionTest MethodMITSUBISHI ENGINEERING JAPAN/5010N6 BK
UL flame retardant rating0.71 mmUL 94V-0
3.2 mmUL 94V-0
1.6 mmUL 94V-0
injectionTest ConditionTest MethodMITSUBISHI ENGINEERING JAPAN/5010N6 BK
Drying Temperature - Vacuum Drying Machine120 °C
Drying time - vacuum dryer5.0 to 8.0 hr
Injection pressure20.0 to 150 Mpa
Injection speed中等偏快
Mold temperature60 to 80 °C
Screw speed80 to 120 rpm
Spray nozzle temperature245 °C
Temperature at the front of the material cylinder250 °C
Temperature at the rear of the barrel235 °C
Temperature in the middle of the barrel240 °C