Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PBT LW9330-BK851 DUPONT USA
Cristin®
Electronic and electrical components,Automotive Applications,Industrial applications,Industrial applications,Box/Shell/Cover/Set,Automotive Applications
Flame retardant,Low warpage,Glass fiber reinforced,Filler: Glass fiber reinf,30% by weight ratio),30% filler by weight,Anti warping,Good surface performance
UL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
thermal performance | Test Condition | Test Method | DUPONT USA/LW9330-BK851 |
---|---|---|---|
Hot deformation temperature | 1.80 Mpa,Unannealed | ISO 75A-1 | 185 ℃ |
1.8MPa,Unannealed | ISO 75-2/A | 185 °C | |
Melting temperature | ISO 11357-3 | 225 °C | |
ISO 3146 | 220 ℃ | ||
UL flame retardant rating | 0.750 mm | UL 94 | HB |
1.50 mm | UL 94 | HB | |
3.00 mm | UL 94 | HB |
mechanical properties | Test Condition | Test Method | DUPONT USA/LW9330-BK851 |
---|---|---|---|
Bending modulus | ISO 178 | 8400 Mpa | |
23℃ | ISO 178 | 8400 MPa | |
Impact strength of cantilever beam gap | -40 °C, Type 1, Notch A | ISO 180 | 7 KJ/m |
23 °C, Type 1, Notch A | ISO 180 | 7 KJ/m | |
Impact strength of simply supported beam without notch | 23 ℃, Type 1, Edgewise | ISO 179 | 55 KJ/m |
Suspended wall beam without notch impact strength | 23 ℃, Type 1 | ISO 180 | 65 KJ/m |
-40 ℃, Type 1 | ISO 180 | 55 KJ/m | |
Tensile modulus | ISO 527-2 | 9800 Mpa | |
23℃ | ISO 527-1 | 9800 MPa | |
Tensile strain | Break | ISO 527-1 | 2.3 % |
Break | ISO 527-2 | 2.3 % | |
tensile strength | Break | ISO 527-2 | 135 Mpa |
Electrical performance | Test Condition | Test Method | DUPONT USA/LW9330-BK851 |
---|---|---|---|
Compared to the anti leakage trace index | IEC 60112 | PLC 1 | |
Surface resistivity | IEC 60093 | >1.0E+15 ohms |
Physical properties | Test Condition | Test Method | DUPONT USA/LW9330-BK851 |
---|---|---|---|
density | ISO 1183 | 1.42 g/cm³ | |
ISO 1183 | 1.42 | ||
MediumDensity | 1.27 g/cm³ | ||
melt mass-flow rate | ISO 1133 | 13 g/10min | |
Melt Volume Flow Rate (MVR) | 250°C/5.0kg | ISO 1133 | 10.0 cm3/10min |
Shrinkage rate | Flow | ISO 294-4 | 0.30 % |
Across Flow | ISO 294-4 | 0.60 % | |
MD | ISO 294-4 | 0.30 % | |
TD | ISO 294-4 | 0.60 % | |
SpecificHeatCapacity of Melt | 1790 J/kg/°C | ||
ThermalConductivityofMelt | 0.28 W/m/K | ||
Top out temperature | 170 °C | ||
Water absorption rate | Equilibrium,23°C,2.00mm,50%RH | ISO 62 | 0.25 % |
Saturation,23°C,2.00mm | ISO 62 | 1.0 % |
impact performance | Test Condition | Test Method | DUPONT USA/LW9330-BK851 |
---|---|---|---|
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 9.0 kJ/m² |
-30°C | ISO 179/1eA | 9.0 kJ/m² | |
-40°C | ISO 179/1eA | 9.0 kJ/m² | |
Impact strength of cantilever beam gap | -40°C | ISO 180/1A | 7.0 kJ/m² |
23°C | ISO 180/1A | 7.0 kJ/m² | |
Impact strength of simply supported beam without notch | -40°C | ISO 179/1eU | 50 kJ/m² |
23°C | ISO 179/1eU | 55 kJ/m² | |
Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 45 kJ/m² |
-40°C | ISO 180/1U | 45 kJ/m² |
flammability | Test Condition | Test Method | DUPONT USA/LW9330-BK851 |
---|---|---|---|
Burning rate | 1.00mm | ISO 3795 | 28 mm/min |
FMVSS flammability | FMVSS302 | B | |
UL flame retardant rating | 0.75mm | UL 94 | HB |
0.75mm | IEC 60695-11-10,-20 | HB | |
1.5mm | IEC 60695-11-10,-20 | HB | |
1.5mm | UL 94 | HB |