Polyester, TS Plenco 01586 (Injection) Plastics Engineering Co.
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Impact resistanceTest ConditionTest MethodPlastics Engineering Co./Plenco 01586 (Injection)
Charpy Notched Impact StrengthASTM D25635.1 J/m
Impact strength of cantilever beam gapASTM D25642 J/m
hardnessTest ConditionTest MethodPlastics Engineering Co./Plenco 01586 (Injection)
Rockwell hardnessE计秤ASTM D78554
Electrical performanceTest ConditionTest MethodPlastics Engineering Co./Plenco 01586 (Injection)
dielectric strength--3ASTM D14913 kV/mm
Volume resistivityASTM D2571.9E+15 ohms·cm
Dissipation Factor1MHzASTM D1500.017
dielectric constant1MHzASTM D1504.40
dielectric strength--4ASTM D14911 kV/mm
Compared to the Leakage Tracking Index (CTI)CTIUL 746PLC 0
arc resistanceASTM D495189 sec
Mechanical propertiesTest ConditionTest MethodPlastics Engineering Co./Plenco 01586 (Injection)
elongation断裂ASTM D6381.1 %
tensile strength ASTM D63864.0 MPa
compressive strengthASTM D695119 MPa
Tensile modulusASTM D63811700 MPa
Flexural modulusASTM D79010300 MPa
bending strengthASTM D790101 MPa
flammabilityTest ConditionTest MethodPlastics Engineering Co./Plenco 01586 (Injection)
UL flame retardant rating1.0mmUL 94V-0
Limiting Oxygen IndexASTM D286341 %
physical property Test ConditionTest MethodPlastics Engineering Co./Plenco 01586 (Injection)
Shrinkage rateMDASTM D9550.37 %
Water absorption rate24hrASTM D5700.060 %
Apparent densityASTM D18950.89 g/cm³
densityASTM D7921.89 g/cm³
Thermal performanceTest ConditionTest MethodPlastics Engineering Co./Plenco 01586 (Injection)
Heat distortion temperature1.8MPa,未退火,HDTASTM D648253 °C
Continuous use temperatureASTM D794217 °C
Linear coefficient of thermal expansionMDASTME8318.6E-05 cm/cm/°C
thermal conductivity100°CASTMC1770.87 W/m/K