Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA6 9B22135 HUV 4Plas
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | 4Plas/ 9B22135 HUV |
---|---|---|---|
Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 14 kJ/m² |
23°C | ISO 180/1A | 17 kJ/m² |
Electrical performance | Test Condition | Test Method | 4Plas/ 9B22135 HUV |
---|---|---|---|
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 1 | |
Volume resistivity | IEC 60093 | 1E+15 ohms·cm | |
Surface Resistivity | IEC 60093 | 1E+13 ohms |
Mechanical properties | Test Condition | Test Method | 4Plas/ 9B22135 HUV |
---|---|---|---|
Tensile strain | 断裂,23°C | ISO 527-2/5 | 3.0 % |
tensile strength | 断裂,23°C | ISO 527-2/5 | 185 MPa |
Tensile modulus | 23°C | ISO 527-2/5 | 10500 MPa |
flammability | Test Condition | Test Method | 4Plas/ 9B22135 HUV |
---|---|---|---|
Hot filament ignition temperature | 2.0mm | IEC 60695-2-13 | 650 °C |
UL flame retardant rating | 3.2mm | UL 94 | HB |
1.6mm | UL 94 | HB |
physical property | Test Condition | Test Method | 4Plas/ 9B22135 HUV |
---|---|---|---|
water content | ISO 960 | <2000 ppm | |
Water absorption rate | 平衡,23°C,50%RH | ISO 62 | 1.9 % |
density | ISO 1183 | 1.40 g/cm³ |
Thermal performance | Test Condition | Test Method | 4Plas/ 9B22135 HUV |
---|---|---|---|
vicat | ISO 306/B | 215 °C | |
melting temperature | ISO 11357 | 223 °C | |
Heat distortion temperature | 0.45MPa,未退火,HDT | ISO 75-2/B | 220 °C |
1.8MPa,未退火,HDT | ISO 75-2/A | 210 °C |
Contact Us
Get App
Top