Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PBT 3309HRLM CELANESE USA
CELANEX®
Automotive sector
Hydrolysis resistance,Easy to process
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Other performance | Test Condition | Test Method | CELANESE USA/3309HRLM |
---|---|---|---|
UL flame retardant rating | UL 94 | HB |
Basic Performance | Test Condition | Test Method | CELANESE USA/3309HRLM |
---|---|---|---|
density | ISO 1183 | 1.53 g/cm³ | |
Shrinkage rate | Flow | ISO 294-4 | 0.3-0.5 % |
横向Flow | ISO 294-4 | 0.7-0.9 % | |
Water absorption rate | 23℃,50%RH | ISO 62 | 0.07 % |
thermal performance | Test Condition | Test Method | CELANESE USA/3309HRLM |
---|---|---|---|
Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 225 °C |
1.8MPa,Unannealed | ISO 75-2/A | 208 °C |
mechanical properties | Test Condition | Test Method | CELANESE USA/3309HRLM |
---|---|---|---|
Bending modulus | 23℃ | ISO 178 | 8900 Mpa |
bending strength | 23℃ | ISO 178 | 210 Mpa |
Charpy Notched Impact Strength | 23℃ | ISO 179/1eA | 6.5 kJ/m² |
elongation | Break | ISO 527-2/1A/5 | 2.7 % |
Suspended wall beam without notch impact strength | 23℃ | ISO 180/1U | 35 kJ/m² |
Tensile modulus | ISO 527-2/1A/1 | 9200 Mpa | |
tensile strength | Break | ISO 527-2/1A/5 | 135 Mpa |
Electrical performance | Test Condition | Test Method | CELANESE USA/3309HRLM |
---|---|---|---|
Compared to the anti leakage trace index | IEC 60112 | PLC 1 | |
Dielectric strength | IEC 60243-1 | 31 KV/mm | |
Dissipation factor | 1MHZ | IEC 60250 | 0.0022 |
Relative permittivity | 100HZ | IEC 60250 | 4.50 |
Volume resistivity | IEC 60093 | 1E+15 ohm·cm |