Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA6 K224-HG8 BK DSM HOLAND
Akulon®
--
Glass fiber reinforced,Filler: Glass fiber reinf,40% filler by weight
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| thermal performance | Test Condition | Test Method | DSM HOLAND/K224-HG8 BK |
|---|---|---|---|
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 220 °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 200 °C | |
| Linear coefficient of thermal expansion | TD | ISO 11359-2 | 5E-05 cm/cm/°C |
| MD | ISO 11359-2 | 2E-05 cm/cm/°C | |
| Melting temperature | ISO 11357-3 | 220 °C |
| mechanical properties | Test Condition | Test Method | DSM HOLAND/K224-HG8 BK |
|---|---|---|---|
| Bending modulus | ISO 178 | 10800 Mpa | |
| bending strength | ISO 178 | 275 Mpa | |
| Tensile modulus | ISO 527-2 | 13000 Mpa | |
| Tensile strain | Break | ISO 527-2 | 3.0 % |
| tensile strength | Break | ISO 527-2 | 205 Mpa |
| Electrical performance | Test Condition | Test Method | DSM HOLAND/K224-HG8 BK |
|---|---|---|---|
| Compared to the anti leakage trace index | IEC 60112 | V | |
| Dielectric strength | IEC 60243-1 | 35 KV/mm | |
| Dissipation factor | 1MHz | IEC 60250 | 0.015 |
| 100Hz | IEC 60250 | 5E-03 | |
| Relative permittivity | 100Hz | IEC 60250 | 3.50 |
| 1MHz | IEC 60250 | 3.30 | |
| Surface resistivity | IEC 60093 | -- ohms | |
| Volume resistivity | IEC 60093 | 1E+14 ohms·cm |
| Physical properties | Test Condition | Test Method | DSM HOLAND/K224-HG8 BK |
|---|---|---|---|
| Shrinkage rate | MD | ISO 294-4 | 0.34 % |
| TD | ISO 294-4 | 0.83 % | |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 1.7 % |
| Saturation,23°C | ISO 62 | 5.5 % |
| impact performance | Test Condition | Test Method | DSM HOLAND/K224-HG8 BK |
|---|---|---|---|
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 85 kJ/m² |
| 23°C | ISO 179/1eU | 95 kJ/m² |
| flammability | Test Condition | Test Method | DSM HOLAND/K224-HG8 BK |
|---|---|---|---|
| UL flame retardant rating | 1.5mm | IEC 60695-11-10,-20 | HB |
| 0.71mm | IEC 60695-11-10,-20 | HB |