plas
Log In

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PTFE 25FR Arlon-MED
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Supplementary InformationTest ConditionTest MethodArlon-MED/25FR
Total Mass Loss125°C>0.24 %
WaterVapor-Recovered0.070 %
filmTest ConditionTest MethodArlon-MED/25FR
Peel strengthInternal Method875.6 N/m
tensile strengthYieldASTM D882A96.5 MPa
thermal performanceTest ConditionTest MethodArlon-MED/25FR
Linear coefficient of thermal expansionMD:--6Internal Method1.6E-05 cm/cm/°C
MD:--7Internal Method1.8E-05 cm/cm/°C
MD:-10to140°C9Internal Method5E-05 cm/cm/°C
MD:--8Internal Method5.9E-05 cm/cm/°C
thermal conductivity100°CASTME12250.45 W/m/K
mechanical propertiesTest ConditionTest MethodArlon-MED/25FR
bending strength23°CASTM D790A241 MPa
Electrical performanceTest ConditionTest MethodArlon-MED/25FR
Dielectric constant23°C,10.0GHzInternal Method3.58
Dissipation factor10.0GHzInternal Method3.5E-03
Surface resistivity0.305mmInternal Method8.9E+08 ohms
Volume resistivity0.305mmInternal Method4.2E+08 ohms·cm
Physical propertiesTest ConditionTest MethodArlon-MED/25FR
densityASTM D792A1.80 g/cm³
Volatile compounds0.0 %
Water absorption rate23°C,24hrInternal Method0.090 %
flammabilityTest ConditionTest MethodArlon-MED/25FR
UL flame retardant ratingUL 94V-0