Impact resistance | Test Condition | Test Method | EVONIK GERMANY/E62S3 |
---|---|---|---|
Charpy Notched Impact Strength | 23℃,局部断裂73°F, Partial Break | ISO 179/1eA | 120 kJ/m² |
-30℃,完全断裂-22°F, Complete Break | ISO 179/1eA | 8 kJ/m² | |
Impact strength of simply supported beam without notch | 23℃23°C | ISO 179/1eU | No Break |
-30℃-30°C | ISO 179/1eU | No Break |
Mechanical properties | Test Condition | Test Method | EVONIK GERMANY/E62S3 |
---|---|---|---|
Tensile modulus | ISO 527-2 | 370 Mpa | |
Shore hardness | 邵氏 D邵氏 D | ISO 868 | 62 |
Tensile strain | 断裂断裂 | ISO 527-2 | > 200 % |
Tensile creep modulus | 1000 hr1000 hr | ISO 899-1 | 200 Mpa |
tensile strength | ---- | ISO 527-2 | 42 Mpa |
50% 应变50% Strain | ISO 527-2 | 23 Mpa |
Electrical performance | Test Condition | Test Method | EVONIK GERMANY/E62S3 |
---|---|---|---|
Dissipation Factor | 23℃,1 MHz23°C, 1 MHz | IEC 60250 | 0.12 |
Compared to the Leakage Tracking Index (CTI) | 解决方案 A解决方案 A | IEC 60112 | PLC 0 |
dielectric strength | IEC 60243-1 | 39 KV/mm | |
relative permittivity | 23℃,1 MHz23°C, 1 MHz | IEC 60250 | 4 |
23℃,100 Hz23°C, 100 Hz | IEC 60250 | 9 | |
Dissipation Factor | 23℃,100 Hz23°C, 100 Hz | IEC 60250 | 0.1 |
Surface Resistivity | IEC 60093 | 100000000000000 ohms | |
Volume resistivity | IEC 60093 | 1000000000000 ohms·cm |
Flame retardant performance | Test Condition | Test Method | EVONIK GERMANY/E62S3 |
---|---|---|---|
1.60 mm??1.6 mm | 1.60mm | UL 94 | HB |
physical property | Test Condition | Test Method | EVONIK GERMANY/E62S3 |
---|---|---|---|
Shrinkage rate | MDFlow | ISO 294-4 | 0.60 - 1.1 % |
Water absorption rate | 饱和,23℃饱和,23℃ | ISO 62 | 1.1 % |
viscosity number | ISO 307 | 190 cm³/g | |
density | ISO 1183 | 1.03 g/cm³ | |
Shrinkage rate | TDAcross Flow | ISO 294-4 | 0.90 - 1.4 % |
Thermal performance | Test Condition | Test Method | EVONIK GERMANY/E62S3 |
---|---|---|---|
Heat distortion temperature | 0.45 MPa,未退火0.45 MPa,未退火,HDT | ISO 75-2/B | 100 °C |
vicat | ---- | ISO 306/B | 110 °C |
Heat distortion temperature | 1.8 MPa,未退火1.8 MPa,未退火,HDT | ISO 75-2/A | 45 °C |
Linear coefficient of thermal expansion | MD:23~55℃MD:23 到 55℃ | ISO 11359-2 | 0.00020 1/℃ |
TD:23~55℃TD:23 到 55℃ | ISO 11359-2 | 0.00020 1/℃ | |
vicat | ---- | ISO 306/A | 165 °C |