Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PPO N190 SABIC INNOVATIVE JAPAN
NORYL™
Electrical applications、electrical equipment
High mobility、Chemical resistance、High rigidity
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/N190 |
---|---|---|---|
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 10 kJ/m² |
-30°C | ISO 179/1eA | 5.0 kJ/m² | |
Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 6.0 kJ/m² |
23°C | ISO 180/1A | 10 kJ/m² |
hardness | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/N190 |
---|---|---|---|
ball-indentation hardness | H 358/30 | ISO 2039-1 | 87.0 Mpa |
Mechanical properties | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/N190 |
---|---|---|---|
Tensile modulus | ISO 527-2/1 | 2300 Mpa | |
tensile strength | 屈服 | ISO 527-2/50 | 50.0 Mpa |
bending strength | ISO 178 | 75.0 Mpa | |
Flexural modulus | ISO 178 | 2200 Mpa | |
Tensile strain | 断裂 | ISO 527-2/50 | 20 % |
屈服 | ISO 527-2/50 | 3.0 % | |
tensile strength | 断裂 | ISO 527-2/50 | 40.0 Mpa |
Electrical performance | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/N190 |
---|---|---|---|
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 2 | |
relative permittivity | 50 Hz | IEC 60250 | 2.70 |
Dissipation Factor | 1 MHz | IEC 60250 | 9.0E-4 |
Volume resistivity | IEC 60093 | 1.0E+15 ohms·cm | |
Dissipation Factor | 60 Hz | IEC 60250 | 4.0E-4 |
relative permittivity | 1 MHz | IEC 60250 | 2.60 |
Dissipation Factor | 50 Hz | IEC 60250 | 4.0E-4 |
Surface Resistivity | IEC 60093 | > 1.0E+15 ohms | |
relative permittivity | 60 Hz | IEC 60250 | 2.70 |
flammability | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/N190 |
---|---|---|---|
UL flame retardant rating | 3.0 mm | UL 94 | 5VA |
Burning wire flammability index | 3.2 mm | IEC 60695-2-12 | 960 °C |
UL flame retardant rating | 1.5 mm | UL 94 | V-0 |
Limiting Oxygen Index | ISO 4589-2 | 30 % |
physical property | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/N190 |
---|---|---|---|
Water absorption rate | 平衡, 23°C, 50% RH | ISO 62 | 0.060 % |
Shrinkage rate | Flow | 内部方法 | 0.50 - 0.70 % |
Melt volume flow rate | 280°C/2.16 kg | ISO 1133 | 8.00 cm3/10min |
Water absorption rate | 饱和, 23°C | ISO 62 | 0.32 % |
Thermal performance | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/N190 |
---|---|---|---|
Linear coefficient of thermal expansion | 横向 : 23 到 80°C | ISO 11359-2 | 9.0E-5 cm/cm/°C |
流动 : 23 到 80°C | ISO 11359-2 | 7.0E-5 cm/cm/°C | |
RTI | UL 746 | 95.0 °C | |
vicat | -- | ISO 306/B120 | 105 °C |
thermal conductivity | ISO 8302 | 0.25 W/m/K | |
Heat distortion temperature | 0.45 MPa, 未退火, 4.00 mm, 100 mm 跨距,HDT | ISO 75-2/Be | 90.0 °C |
ball-indentation hardness | 73 到 77°C | IEC 60695-10-2 | 通过 |
95°C8 | IEC 60695-10-2 | 通过 | |
vicat | -- | ISO 306/A50 | 110 °C |
Heat distortion temperature | 1.8 MPa, 未退火, 4.00 mm, 100 mm 跨距,HDT | ISO 75-2/Ae | 80.0 °C |
vicat | -- | ISO 306/B50 | 95.0 °C |
RTI Imp | UL 746 | 80.0 °C | |
RTI Elec | UL 746 | 95.0 °C |
injection | Test Condition | Test Method | SABIC INNOVATIVE JAPAN/N190 |
---|---|---|---|
drying time | 2.0 to 3.0 hr | ||
Temperature in the middle of the barrel | 240 to 260 °C | ||
Temperature at the rear of the barrel | 220 to 240 °C | ||
Processing (melt) temperature | 260 to 280 °C | ||
Hopper temperature | 60 to 80 °C | ||
drying temperature | 80 to 100 °C | ||
Temperature at the front of the material cylinder | 260 to 280 °C | ||
Temperature | 60 to 80 °C | ||
Spray nozzle temperature | 240 to 260 °C |
Contact Us
Get App
Top