Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PPS OE006 SABIC INNOVATIVE US
LNP™ STAT-KON™
Automotive Applications
Carbon fiber reinforced,High impact resistance,Filler: Carbon fiber rein,30% filler by weight
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
thermal performance | Test Condition | Test Method | SABIC INNOVATIVE US/OE006 |
---|---|---|---|
Linear coefficient of thermal expansion | MD:-40to40°C | ASTME831 | 7.2E-06 cm/cm/°C |
TD:-40to40°C | ISO 11359-2 | 4.1E-05 cm/cm/°C | |
TD:-40to40°C | ASTME831 | 4E-05 cm/cm/°C | |
MD:-40to40°C | ISO 11359-2 | 8.7E-06 cm/cm/°C |
mechanical properties | Test Condition | Test Method | SABIC INNOVATIVE US/OE006 |
---|---|---|---|
Bending modulus | ASTM D790 | 23500 Mpa | |
ISO 178 | 24700 Mpa | ||
bending strength | ISO 178 | 312 Mpa | |
ASTM D790 | 305 Mpa | ||
elongation | Break | ASTM D638 | 1.1 % |
Friction coefficient | Dynamic | ASTM D3702Modified | 1.6 |
Static | ASTM D3702Modified | 1.4 | |
Tensile modulus | ASTM D638 | 32800 Mpa | |
ISO 527-2/1 | 25500 Mpa | ||
Tensile strain | Break | ISO 527-2 | 1.0 % |
tensile strength | Break | ISO 527-2 | 204 Mpa |
Break | ASTM D638 | 210 Mpa | |
Wear factor | Washer | ASTM D3702Modified | 857 10^-10in^5-min/ft-lb-hr |
Electrical performance | Test Condition | Test Method | SABIC INNOVATIVE US/OE006 |
---|---|---|---|
Surface resistivity | ASTM D257 | 1.0E+2to1.0E+6 ohms |
Physical properties | Test Condition | Test Method | SABIC INNOVATIVE US/OE006 |
---|---|---|---|
Shrinkage rate | TD:24hr | ASTM D955 | 0.40 % |
TD:24hr | ISO 294-4 | 0.40 % | |
MD:24hr | ASTM D955 | 0.10 % | |
MD:24hr | ISO 294-4 | 0.080 % | |
Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.030 % |
24hr,50%RH | ASTM D570 | 0.020 % |
impact performance | Test Condition | Test Method | SABIC INNOVATIVE US/OE006 |
---|---|---|---|
Dart impact | 23°C,EnergyatPeakLoad | ASTM D3763 | 3.30 J |
Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 5.2 kJ/m² |
Multi axis Instrumented Impact Energy | ISO 6603-2 | 1.70 J | |
Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 28 kJ/m² |
flammability | Test Condition | Test Method | SABIC INNOVATIVE US/OE006 |
---|---|---|---|
UL flame retardant rating | 1.0mm | UL 94 | V-0 |