Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PPS 1140L6 BK CELANESE USA
FORTRON®
fibre,Bottle cap
Flame retardant,Glass fiber reinforced,High temperature resistan
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| Supplementary Information | Test Condition | Test Method | CELANESE USA/1140L6 BK |
|---|---|---|---|
| CSARating | 8.40E-7mm | CSAF-1 | A00 |
| hardness | Test Condition | Test Method | CELANESE USA/1140L6 BK |
|---|---|---|---|
| Rockwell hardness | M-Scale | ASTM D785 | 100 |
| M-Scale | ISO 2039-2 | 100 |
| Basic Performance | Test Condition | Test Method | CELANESE USA/1140L6 BK |
|---|---|---|---|
| Water absorption rate | ISO 62 | 0.02 % |
| thermal performance | Test Condition | Test Method | CELANESE USA/1140L6 BK |
|---|---|---|---|
| Glass transition temperature | ISO 11357-2 | 90.0 °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 265 °C |
| 0.45MPa,Annealed | ASTM D648 | 280 °C | |
| 1.80Mpa | ISO 75-1 | 270 °C | |
| 8.0MPa,Unannealed | ISO 75-2/C | 215 °C | |
| 1.8MPa,Unannealed | ISO 75-2/A | 270 °C | |
| Linear coefficient of thermal expansion | TD | ISO 11359-2 | 4.2E-05 cm/cm/°C |
| MD | ISO 11359-2 | 2.6E-05 cm/cm/°C | |
| Melting temperature | ISO 11357-3 | 280 °C | |
| UL flame retardant rating | UL 94 | V-0 |
| mechanical properties | Test Condition | Test Method | CELANESE USA/1140L6 BK |
|---|---|---|---|
| Bending modulus | ISO 178 | 14500 Mpa | |
| 23°C | ISO 178 | 14500 Mpa | |
| bending strength | ISO 178 | 285 Mpa | |
| elongation | Break | ISO 527-1 | 1.9 % |
| Break,23°C | ASTM D638 | 2.0 % | |
| Impact strength of cantilever beam gap | 23℃ | ISO 180/1A | 10 kJ/m² |
| Rockwell hardness | ISO 2039-2 | 100 M-scale | |
| Tensile modulus | ISO 527-2/1A/1 | 14700 Mpa | |
| ISO 527-1 | 14700 Mpa | ||
| Tensile strain | Break | ISO 527-2/1A/5 | 1.9 % |
| tensile strength | Break,23°C | ASTM D638 | 200 Mpa |
| ISO 527-1 | 195 Mpa | ||
| Break | ISO 527-2/1A/5 | 195 Mpa |
| Electrical performance | Test Condition | Test Method | CELANESE USA/1140L6 BK |
|---|---|---|---|
| Arc resistance | ASTM D495 | 134 sec | |
| Compared to the anti leakage trace index | IEC 60112 | V | |
| Dielectric constant | 1MHz | ASTM D150 | 3.50 |
| 1kHz | ASTM D150 | 3.50 | |
| Dielectric strength | IEC 60243-1 | 28 KV/mm | |
| ASTM D149 | 15 KV/mm | ||
| Dissipation factor | 1MHz | IEC 60250 | 2E-03 |
| 1MHz | ASTM D150 | 1E-03 | |
| 1kHz | ASTM D150 | 1E-03 | |
| Relative permittivity | 1MHz | IEC 60250 | 4.10 |
| Surface resistivity | IEC 60093 | >1.0E+15 ohms | |
| Volume resistivity | ASTM D257 | 1E+16 ohms·cm | |
| IEC 60093 | >1.0E+15 ohms·cm |
| Physical properties | Test Condition | Test Method | CELANESE USA/1140L6 BK |
|---|---|---|---|
| density | ISO 1183 | 1.65 g/cm³ | |
| ASTM D792 | 1.60 g/cm³ | ||
| melt mass-flow rate | ASTM D1238 | 19 g/10min | |
| Shrinkage rate | ISO 2577 | 0.2-0.6 % | |
| MD | ISO 294-4 | 0.20-0.60 % | |
| MD | ASTM D955 | 0.20-0.30 % | |
| TD | ISO 294-4 | 0.40-0.60 % | |
| TD | ASTM D955 | 0.50-0.70 % | |
| SpecificHeatCapacity of Melt | Internal Method | 1500 J/kg/°C | |
| Specific volume | ASTM D792 | 0.625 cm³/g | |
| Spiral flow length | Internal Method | 21.5 | |
| Water absorption rate | Saturation,23°C | ISO 62 | 0.020 % |
| impact performance | Test Condition | Test Method | CELANESE USA/1140L6 BK |
|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 10 kJ/m² |
| -30°C | ISO 179/1eA | 10 kJ/m² | |
| Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 10 kJ/m² |
| 23°C | ISO 180/1A | 10 kJ/m² | |
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 53 kJ/m² |
| 23°C | ISO 179/1eU | 53 kJ/m² | |
| Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 34 kJ/m² |
| flammability | Test Condition | Test Method | CELANESE USA/1140L6 BK |
|---|---|---|---|
| UL flame retardant rating | 0.38mm | UL 94 | V-0 |
| 1.5mm | UL 94 | V-0 |